0102030405
XINNA F33 IV Filters 1.2/2.0/3.0/5.0μm for Infusion Sets - Quality Products from China Suppliers & Factory
Product Introduction
Potential risks caused by harmful particles, microbial contamination, and air micro embolism should be considered in infusion therapy, drug preparation, and mixing processes. F33 IV filter is designed for use in filtration of intravenous for removal of particles large than 1.2/2.0/3.0/5.0μm.
F33 IV Filter is an air eliminating filter for the removal of inadvertent particulate debris and other components like incomplete mixing of drugs and entrained air in catheter which may be found in solutions intended for intravenous use. The filtration efficiency of the membrane and the overall design of the filter can impact the safety of drug delivery for human beings.
It is inbuilt with low binding Hydrophilic Polypropylene filter membrane lower the loss of drug and active ingredients, and dual vents design allows air elimination in any position. ensuring the safety and effectiveness of intravenous.
Features
- Range of pore size options
- Low protein binding & Low dissolution
- Dual vent design ensures quick Priming and air elimination
- Compatibility with TPN & chemotherapeutic agents
- Maximizes filtration area with compact construction
- Lightproof-colored housings for light sensitive drugs is available
- Printing available for ease of product identification
Characteristics
| Specification Parameter | Details |
|---|---|
| Dimensions | 57*29*0.94mm (inlet/outlet connector included) |
| Connector | Φ 3.1mm/3.6mm |
| Max burst pressure | 3.6bar (52.5psi) |
| Priming volume | ≤2.0ml |
| Venting air flow rate | 25ml/min@5kpa |
| Operating temp | 10-30℃ |
| Pyrogenicity | ≤0.5EU/ml |
| Storage temp | 5-40℃ |
| Sterilization | Ethlene oxide (Max 60℃) |
Performance
Package
3000pcs/carton, 4 inner PE bags with 750 pcs inside each. Each bag is sealed separately and cushion between each other.
Each bag is labeled with information as following, different lots in one box are closed separately and labeled seperately to prevent mix up.
Label information
| Field | Field Value | Reference Field |
|---|---|---|
| Name | Specifications | Batach No. |
| Model | Quantity | Operator No. |
Warnings
- Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
- Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling. Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
- Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
- It's not recommended to use alcohol or any kind of disinfactant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
- Blood delivery is not allowed, the filter clogs with blood or red blood cells. Filters with 0.2μm filter media is not recommended for TPN and lipids administration.
- Rigorous testing is recommended before marketing if drugs is not common.
- Contact with Xinna Medical for more information if any doubt is exist advanced.
Ordering information
| Appearance | Housing | Filter media options | Mold | Connector | Vents |
|---|---|---|---|---|---|
| GLOL | 033 | 500 | F | OY | Y |
| GLBC | - | 300 | - | - | - |
| GLBZ | - | 200 | - | - | - |
| - | - | 120 | - | - | - |
Frequently Asked Questions
What is the primary function of the F33 IV Filter?
The F33 IV Filter is designed to filter intravenous solutions, effectively removing harmful particles larger than 1.2/2.0/3.0/5.0μm, microbial contamination, and preventing air micro embolism during infusion therapy.
What membrane features help prevent drug loss?
The filter is built with a low-binding Hydrophilic Polypropylene filter membrane, which minimizes the loss of drugs and active ingredients, ensuring the effective delivery of the intended therapy.
Can the F33 IV Filter eliminate air in any orientation?
Yes, the filter features a dual vent design that ensures quick priming and reliable air elimination in any position.
Why should alcohol be kept away from the filter housing and venting membrane?
Alcohol can cause visible or invisible damage to the ABS-based housing. Additionally, direct contact with alcohol or disinfectants will cause the hydrophobic PTFE venting membrane to temporarily become hydrophilic until it completely dries, compromising its functionality.
Can this filter be used for blood delivery or TPN administration?
No, blood delivery is not allowed as it will clog the filter. Furthermore, filters with 0.2μm filter media are not recommended for TPN (Total Parenteral Nutrition) and lipid administrations.
How is the F33 IV Filter packaged to prevent product mix-ups?
It is packaged with 3000pcs per carton, split into 4 inner PE bags of 750pcs. Each bag is sealed and cushioned separately. To prevent mix-ups, different lots within the same box are packaged and labeled separately with specific batch and operator numbers.