XINNA F33 IV Filter for Infusion Sets - 1.2/2.0/3.0/5.0μm | China Suppliers & Factory
Product Introduction
Features
- Range of pore size options
- Low protein binding & Low dissolution
- Dual vent design ensures quick Priming and air elimination
- Compatibility with TPN & chemotherapeutic agents
- Maximizes filtration area with compact construction
- Lightproof-colored housings for light sensitive drugs is available
- Printing available for ease of product identification
Characteristics
| Parameter | Specification |
|---|---|
| Dimensions | 57*29*0.94mm ( inlet/outlet connector included) |
| Connector | Φ 3.1mm/3.6mm |
| Max burst pressure | 3.6bar (52.5psi) |
| Priming volume | ≤2.0ml |
| Venting air flow rate | 25ml/min@5kpa |
| Operating temp | 10-30℃ |
| Pyrogenicity | ≤0.5EU/ml |
| Storage temp | 5-40℃ |
| Sterilization | Ethlene oxide (Max 60℃) |
Performance
Package
Label information
| Name | Specifications | Batch No. |
| Model | Quantity | Operator No. |
Warnings
- Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
- Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling. Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
- Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
- It's not recommended to use alcohol or any kind of disinfectant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
- Blood delivery is not allowed, the filter clogs with blood or red blood cells. Filters with 0.2μm filter media is not recommended for TPN and lipids administration.
- Rigorous testing is recommended before marketing if drugs is not common.
- Contact with Xinna Medical for more information if any doubt is exist advanced.
Ordering information
| Appearance | Housing | Filter media options | Mold | Connector | Vents |
|---|---|---|---|---|---|
| GLOL | 033 | 500 | F | OY | Y |
| GLBC | 300 | ||||
| GLBZ | 200 | ||||
| 120 |
Frequently Asked Questions (FAQ)
What is the primary function of the F33 IV Filter?
The F33 IV filter is designed to remove particles larger than 1.2/2.0/3.0/5.0μm, inadvertent particulate debris, incomplete drug mixtures, and entrained air in the catheter during intravenous infusion therapy.
How does the membrane design affect drug delivery?
It is built with a low-binding Hydrophilic Polypropylene filter membrane that minimizes the loss of drugs and active ingredients, while its dual vents design ensures effective air elimination in any position.
Can the F33 IV Filter be used for blood delivery?
No, blood delivery is not allowed as the filter will clog with blood or red blood cells. Additionally, filters with 0.2μm filter media are not recommended for TPN and lipids administration.
What are the warning guidelines regarding alcohol and disinfectants?
Alcohol must not contact the housing as it will damage the ABS-based structure. It is also not recommended to use alcohol or disinfectants on the venting membrane, as the PTFE membrane will remain hydrophilic until fully dried.
What are the package specifications and storage conditions?
The filters are packaged 3000pcs/carton, containing 4 inner PE bags with 750pcs each. They should be stored at temperatures between 5-40℃, and the operating temperature should be maintained between 10-30℃.