Introducing our premium range of products, expertly manufactured in China by top-tier suppliers and factories. Our commitment to quality and innovation sets us apart in the competitive market. As a leading supplier, we ensure that every product meets rigorous standards, delivering exceptional performance and durability. Partnering with reliable factories in China allows us to offer you unmatched prices without compromising on quality. Explore our extensive selection and discover why we are the preferred choice for businesses seeking reliable products from trusted suppliers in China. Elevate your offerings with our meticulously crafted items today!
  • Category F
  • Filter Membrane Hydrophilic Polypropylene
  • Vent Hydrophobic PTFE membrane
  • Housing mAbs
  • Removal of Particles options 1.2/2.0/3.0/5.0μm
  • Standard YY0286.1 GB8368-2018 ISO 8536-4

Product Introduction

Potential risks caused by harmful particles, microbial contamination, and air micro embolism should be considered in infusion therapy, drug preparation, and mixing processes. F33 IV filter is designed for use in filtration of intravenous for removal of particles large than 1.2/2.0/3.0/5.0μm.

F33 IV Filter is an air eliminating filter for the removal of inadvertent particulate debris and other components like incomplete mixing of drugs and entrained air in catheter which may be found in solutions intended for intravenous use. The filtration efficiency of the membrane and the overall design of the filter can impact the safety of drug delivery for human beings.

It is inbuilt with low binding Hydrophilic Polypropylene filter membrane lower the loss of drug and active ingredients, and dual vents design allows air elimination in any position. ensuring the safety and effectiveness of intravenous.

Features

  • Range of pore size options
  • Low protein binding & Low dissolution
  • Dual vent design ensures quick Priming and air elimination
  • Compatibility with TPN & chemotherapeutic agents
  • Maximizes filtration area with compact construction
  • Lightproof-colored housings for light sensitive drugs is available
  • Printing available for ease of product identification
in-line infusion filter in PES with 2 window PTFE vents

Characteristics

Dimensions 57*29*0.94mm ( inlet/outlet connector included)
Connector Φ 3.1mm/3.6mm
Max burst pressure 3.6bar (52.5psi)
Priming volume ≤2.0ml
Venting air flow rate 25ml/min@5kpa
Operating temp 10-30℃
Pyrogenicity ≤0.5EU/ml
Storage temp 5-40℃
Sterilization Ethlene oxide (Max 60℃)

Performance

F33

Package

3000pcs/carton, 4 inner PE bags with 750 pcs inside each. Each bag is sealed separately and cushion between each other.

Each bag is labeled with information as following, different lots in one box are closed separately and labeled seperately to prevent mix up.

Label information

Name Specifications Batach No.
Model Quantity Operator No.

Warnings

Usage Warnings & Guidelines
  • Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
  • Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling. Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
  • Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
  • It's not recommended to use alcohol or any kind of disinfactant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
  • Blood delivery is not allowed, the filter clogs with blood or red blood cells. Filters with 0.2μm filter media is not recommended for TPN and lipids administration.
  • Rigorous testing is recommended before marketing if drugs is not common.
  • Contact with Xinna Medical for more information if any doubt is exist advanced.

Ordering information

Appearance Housing Filter media options Mold Connector Vents
GLOL 033 500 F OY Y
GLBC 300
GLBZ 200
120

Frequently Asked Questions

What is the primary function of the F33 IV Filter?

The F33 IV Filter is designed to remove harmful particles larger than 1.2/2.0/3.0/5.0μm, microbial contamination, and air micro embolism during intravenous infusion therapy, drug preparation, and mixing processes.

How does the membrane design protect drug efficacy?

It features a low binding Hydrophilic Polypropylene filter membrane, which minimizes the loss of active drug ingredients, ensuring both safety and effectiveness during delivery.

Can the F33 IV Filter be used for blood transfusions or TPN?

No, blood delivery is not allowed as the filter will clog with blood or red blood cells. Additionally, filters with 0.2μm filter media are not recommended for TPN and lipids administration.

Why must alcohol be kept away from the filter housing and membrane?

Alcohol can cause visible or invisible damage to the ABS-based housing. Direct contact with the venting membrane is also discouraged, as alcohol or disinfectants will make the PTFE membrane hydrophilic until it dries.

What are the packaging specifications for bulk orders?

Each carton contains 3000 pcs, divided into 4 inner PE bags of 750 pcs. Each bag is sealed separately with protective cushioning and labeled with distinct lot numbers to prevent mix-ups.

What should be done if using uncommon drugs with the filter?

Rigorous compatibility testing is highly recommended before marketing if the drugs being administered are not common. You can contact Xinna Medical for advanced technical support.