Leave Your Message
XINNA D33 Dual Filtration Layer IV Filter 0.2/1.2 μm - Top China Suppliers & Factory Quality
Hot Products

XINNA D33 Dual Filtration Layer IV Filter 0.2/1.2 μm - Top China Suppliers & Factory Quality

Introducing our premium product sourced directly from reputable China suppliers. Our factory is committed to delivering high-quality items that meet international standards. Each product undergoes rigorous quality control to ensure durability and performance. By partnering with leading suppliers in China, we guarantee competitive pricing and prompt delivery. Trust our factory for all your needs, as we specialize in providing exceptional products tailored to your specifications. Experience the best of China with our trusted suppliers and factory expertise today!
  • Category X
  • Filter Media Hydrophilic PES
  • Vent hydrophobic PTFE
  • Housing mAbs
  • Removal of Particles options 1.2/0.2μm/B.diminuta
  • Standard YY0286.1 GB8368-2018 ISO 8536-4 YY0918 YY1551

Product Introduction

The special design of D33 dual layer IV filters is an innovative design to solve multiple problems in the IV market such as prevent particle administration to patients, reducing postoperative phlebitis rates in surgical patients, preserving organ functions, and reducing the incidence of the systemic inflammatory response syndrome (SIRS).

This product developed with two opposite layers of Asymmetric hydrophilic Polyethersulphone membrane built in a large volumes mAbs polymer housing, Maximized the filtration area and guaranteeing high-end flow rates and fast priming performance with quad vents both side in total, better construction mechanical strength with pressure infusion applications with infusion pumps or similar equipment as well and gravity IV solution also.

D33-022 filter could work as a barrier to bacterial contaminants prior to prevent bacterium administration to patients and use in the filtration of intravenous or other aqueous solutions for removal of particles larger than 0.2µm. And both D33-022 & D33-120 IV filters increased patients’ satisfaction perceived for the vascular access management and reducing the discomfort associated with short peripheral venous cannulation.

We highly recommend that all Intravenous in-line filters should be positioned as closed as possible to the patient to decrease the overall particulate contamination which inside the IV set already or other extension sets maximally.

Features

  • Maximized Filtration area
  • Barrier to bacterial contaminants
  • Low drug binding PES membrane
  • Quad vent design ensure quick air elimination & priming
  • Options of pore size enable retention of bacteria, particles and debris
  • Removal of air from liquid solutions
  • Satisfied with Pumps or gravity solutions
  • Customization capabilities on pad printing
  • Colored lightproof housing for light sensitive drugs
0.22 μm double deck infusion filter

Specifications

Dimensions 60*29.5*0.95mm ( inlet/outlet connector included)
Connector Φ 3.1mm/3.6mm
Max burst pressure 3.6bar (52.5psi)
Venting air flow rate 25ml/min@5kpa
Priming volume ≤2.0ml
Operating temp 10-30℃
Pyrogenicity ≤0.5EU/ml
Storage temp 5-40℃
Sterilization Ethlene oxide (Max 60℃)

Applications

Drug delivery
IV Solutions
Infusion therapy
TPN and Lipid solutions
Antibiotic therapy
Apheresis solutions
Chemotherapies
Intravenous medication
TPN and lipid solutions(1.2μm)

Performance

X33 infusion filter

Package

2000pcs/carton, 8 inner PE bags with 250pcs inside each. Each bag is sealed separately and cushion between each other.

Each bag is labeled with information as following, different lots in one box are closed separately and labeled seperately to prevent mix up.

Label Information

Field 1 Field 2 Field 3
Name Specifications Batch No.
Model Quantity Operator No.
Warnings
  • Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
  • Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling.
  • Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
  • Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
  • It's not recommended to use alcohol or any kind of disinfactant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
  • Blood delivery is not allowed, the filter clogs with blood or red blood cells.
  • Filters with 0.2μm filter media is not recommended for TPN and lipids administration.
  • Rigorous testing is recommended before marketing if drugs is not common.
  • Contact with Xinna Medical for more information if any doubt is exist advanced.

Ordering Information

Appearance Housing Filter Media Options Mold Connector Vents
GLOL D33 022 F OY Y
GLBC - 120 - - -
GLBZ - - - - -

Frequently Asked Questions (FAQ)

What are the clinical benefits of using the D33 dual layer IV filter?
The D33 dual layer IV filter prevents particulate and bacterial transmission to patients, lowers postoperative phlebitis rates in surgical patients, helps preserve organ functions, and reduces the incidence of systemic inflammatory response syndrome (SIRS).
Can D33 filters be used with both gravity infusion and infusion pumps?
Yes, the D33 filter is built with robust mechanical strength supporting maximum burst pressure up to 3.6 bar (52.5 psi), making it fully compatible with both gravity IV solutions and pressure infusion pumps.
Which pore size should be selected for TPN and lipid solutions?
A pore size of 1.2μm (D33-120) is recommended for TPN and lipid solutions. The 0.2μm filter media is not recommended for TPN and lipids administration.
Can the D33 filter be used for whole blood or red blood cell delivery?
No, blood delivery is strictly not allowed as the filter media will clog with whole blood or red blood cells.
What are the critical handling cautions regarding alcohol and adhesives?
Alcohol must not come into contact with the ABS housing or the PTFE venting membrane, as it can cause structural damage or render venting membranes hydrophilic until dried. Additionally, glue must never touch the hydrophilic PES membrane to prevent breakdown.
Where is the recommended installation position for the in-line IV filter?
It is highly recommended that all in-line IV filters be placed as close as possible to the patient to maximally prevent particulate contamination from within the IV line and extension sets from entering the bloodstream.