XINNA D33 Dual Filtration Layer IV Filter 0.2/1.2 μm - Quality China Suppliers and Factory Direct Offer
Product Introduction
The special design of D33 dual layer IV filters is an innovative design to solve multiple problems in the IV market such as prevent particle administration to patients, reducing postoperative phlebitis rates in surgical patients, preserving organ functions, and reducing the incidence of the systemic inflammatory response syndrome (SIRS).
This product developed with two opposite layers of Asymmetric hydrophilic Polyethersulphone membrane built in a large volumes mAbs polymer housing, Maximized the filtration area and guaranteeing high-end flow rates and fast priming performance with quad vents both side in total, better construction mechanical strength with pressure infusion applications with infusion pumps or similar equipment as well and gravity IV solution also.
D33-022 filter could work as a barrier to bacterial contaminants prior to prevent bacterium administration to patients and use in the filtration of intravenous or other aqueous solutions for removal of particles larger than 0.2µm. And both D33-022 & D33-120 IV filters increased patients’ satisfaction perceived for the vascular access management and reducing the discomfort associated with short peripheral venous cannulation.
We highly recommend that all Intravenous in-line filters should be positioned as closed as possible to the patient to decrease the overall particulate contamination which inside the IV set already or other extension sets maximally.
Features
- Maximized Filtration area
- Barrier to bacterial contaminants
- Low drug binding PES membrane
- Quad vent design ensure quick air elimination & priming
- Options of pore size enable retention of bacteria, particles and debris
- Removal of air from liquid solutions
- Satisfied with Pumps or gravity solutions
- Customization capabilities on pad printing
- Colored lightproof housing for light sensitive drugs
Specifications
| Parameter | Specification Details |
|---|---|
| Dimensions | 60*29.5*0.95mm (inlet/outlet connector included) |
| Connector | Φ 3.1mm/3.6mm |
| Max burst pressure | 3.6bar (52.5psi) |
| Venting air flow rate | 25ml/min@5kpa |
| Priming volume | ≤2.0ml |
| Operating temp | 10-30℃ |
| Pyrogenicity | ≤0.5EU/ml |
| Storage temp | 5-40℃ |
| Sterilization | Ethlene oxide (Max 60℃) |
Applications
Drug delivery
IV Solutions
Infusion therapy
TPN and Lipid solutions
Antibiotic therapy
Apheresis solutions
Chemotherapies
Intravenous medication
TPN and lipid solutions (1.2μm)
Performance
Package & Label Information
Packaging Details: 2000pcs/carton, 8 inner PE bags with 250pcs inside each. Each bag is sealed separately and cushioned between each other. Each bag is labeled with information as follows. Different lots in one box are closed separately and labeled separately to prevent mix-up.
| Label Information Matrix | ||
|---|---|---|
| Name | Specifications | Batch No. |
| Model | Quantity | Operator No. |
Warnings
- Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
- Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling.
- Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
- Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visibly or invisibly.
- It's not recommended to use alcohol or any kind of disinfectant in direct contact with venting membrane; PTFE membrane will become hydrophilic until dried.
- Blood delivery is not allowed, the filter clogs with blood or red blood cells.
- Filters with 0.2μm filter media are not recommended for TPN and lipids administration.
- Rigorous testing is recommended before marketing if drugs are not common.
- Contact with Xinna Medical for more information if any doubt exists in advance.
Ordering Information
| Appearance | Housing | Filter Media Options | Mold | Connector | Vents |
|---|---|---|---|---|---|
| GLOL | D33 | 022 | F | OY | Y |
| GLBC | - | 120 | - | - | - |
| GLBZ | - | - | - | - | - |
Frequently Asked Questions (FAQ)
What are the primary clinical benefits of the D33 dual layer IV filters?
The D33 dual layer IV filter is designed to solve multiple clinical issues, including preventing particle administration to patients, reducing postoperative phlebitis rates in surgical patients, preserving organ functions, and reducing the incidence of systemic inflammatory response syndrome (SIRS).
Where should the intravenous in-line filters be positioned during use?
It is highly recommended to position all intravenous in-line filters as close to the patient as possible. This layout maximally decreases overall particulate contamination originating inside the IV set or other extension sets.
Can the D33-022 filter be used for TPN and lipid administration?
No, filters with 0.2μm filter media (such as the D33-022) are not recommended for TPN and lipids administration. For TPN and lipid solutions, a 1.2μm filter option is appropriate.
Why is it critical to keep alcohol away from the filter housing and venting membrane?
Alcohol contact must be avoided because it can damage the ABS-based housing (either visibly or invisibly). Furthermore, direct contact with the venting PTFE membrane will temporarily turn it hydrophilic until it completely dries, compromising its performance.
Can these filters be used for blood transfusions or blood delivery?
No, blood delivery is strictly not allowed. The filter media will clog when exposed to blood or red blood cells.
What components make up the D33 filter's membrane and housing structure?
The D33 filter features two opposite layers of Asymmetric hydrophilic Polyethersulphone (PES) membrane housed in a large-volume mAbs polymer housing, complete with quad vents on both sides for optimized flow rates and fast priming.