Leave Your Message
XINNA D33 Dual Filtration IV Filter 0.2/1.2 μm - Quality Manufacturer in China | Trusted Suppliers & Factory
Hot Products

XINNA D33 Dual Filtration IV Filter 0.2/1.2 μm - Quality Manufacturer in China | Trusted Suppliers & Factory

Discover top-quality products sourced directly from China, where our trusted suppliers and efficient factory ensure the best manufacturing standards. Our extensive range caters to various needs, providing exceptional value and unmatched reliability. Experience the excellence of Chinese craftsmanship with our products, designed to meet global standards while maintaining affordability. Partner with us to access premium items that reflect the dedication of our suppliers and the expertise of our factory in delivering the finest goods available on the market. Elevate your business with products that guarantee both quality and competitive pricing
  • Category X
  • Filter Media Hydrophilic PES
  • Vent hydrophobic PTFE
  • Housing mAbs
  • Removal of Particles options 1.2/0.2μm/B.diminuta
  • Standard YY0286.1 GB8368-2018 ISO 8536-4 YY0918 YY1551

Product Introduction

The special design of D33 dual layer IV filters is an innovative design to solve multiple problems in the IV market such as prevent particle administration to patients, reducing postoperative phlebitis rates in surgical patients, preserving organ functions, and reducing the incidence of the systemic inflammatory response syndrome (SIRS).
This product developed with two opposite layers of Asymmetric hydrophilic Polyethersulphone membrane built in a large volumes mAbs polymer housing, Maximized the filtration area and guaranteeing high-end flow rates and fast priming performance with quad vents both side in total, better construction mechanical strength with pressure infusion applications with infusion pumps or similar equipment as well and gravity IV solution also.
D33-022 filter could work as a barrier to bacterial contaminants prior to prevent bacterium administration to patients and use in the filtration of intravenous or other aqueous solutions for removal of particles larger than 0.2µm. And both D33-022 & D33-120 IV filters increased patients’ satisfaction perceived for the vascular access management and reducing the discomfort associated with short peripheral venous cannulation.
We highly recommend that all Intravenous in-line filters should be positioned as closed as possible to the patient to decrease the overall particulate contamination which inside the IV set already or other extension sets maximally.

Features

  • Maximized Filtration area
  • Barrier to bacterial contaminants
  • Low drug binding PES membrane
  • Quad vent design ensure quick air elimination & priming
  • Options of pore size enable retention of bacteria, particles and debris
  • Removal of air from liquid solutions
  • Satisfied with Pumps or gravity solutions
  • Customization capabilities on pad printing
  • Colored lightproof housing for light sensitive drugs
0.22 um double deck infusion filter

Specifications

Dimensions 60*29.5*0.95mm (inlet/outlet connector included)
Connector Φ 3.1mm/3.6mm
Max burst pressure 3.6bar (52.5psi)
Venting air flow rate 25ml/min@5kpa
Priming volume ≤2.0ml
Operating temp 10-30℃
Pyrogenicity ≤0.5EU/ml
Storage temp 5-40℃
Sterilization Ethlene oxide (Max 60℃)

Applications

  • Drug delivery
  • IV Solutions
  • Infusion therapy
  • TPN and Lipid solutions
  • Antibiotic therapy
  • Apheresis solutions
  • Chemotherapies
  • Intravenous medication
  • TPN and lipid solutions (1.2μm)

Performance

X33 infusion filter

Package

2000pcs/carton, 8 inner PE bags with 250pcs inside each. Each bag is sealed separately and cushion between each other.
Each bag is labeled with information as following, different lots in one box are closed separately and labeled separately to prevent mix up.

Label Information

Name Specifications Batch No.
Model Quantity Operator No.

Warnings

Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling.
Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
It's not recommended to use alcohol or any kind of disinfectant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
Blood delivery is not allowed, the filter clogs with blood or red blood cells.
Filters with 0.2μm filter media is not recommended for TPN and lipids administration.
Rigorous testing is recommended before marketing if drugs is not common.
Contact with Xinna Medical for more information if any doubt is exist advanced.

Ordering Information

Appearance Housing Filter media options Mold Connector Vents
GLOL D33 022 F OY Y
GLBC 120
GLBZ

Frequently Asked Questions

What are the primary clinical benefits of using the D33 dual-layer IV filter?
The D33 dual-layer IV filter is designed to prevent particle administration to patients, reduce postoperative phlebitis rates in surgical patients, preserve organ functions, and reduce the incidence of systemic inflammatory response syndrome (SIRS).
Can the D33 filter be used with pressure infusion pumps?
Yes, the D33 filter is built with enhanced mechanical strength, making it compatible with pressure infusion applications using infusion pumps or similar equipment, as well as gravity IV solutions.
Is the D33 filter suitable for blood transfusions or lipid infusions?
No, blood delivery is not allowed as the filter will clog with blood or red blood cells. Additionally, 0.2μm filter media is not recommended for TPN and lipids administration; a 1.2μm filter option should be used instead.
Why must alcohol be kept away from the filter housing and venting membrane?
Alcohol contact can cause visible or invisible damage to the ABS-based housing. Furthermore, direct contact with the PTFE venting membrane will make it hydrophilic until dried, compromising its performance.
What is the packaging specification for bulk orders?
The standard packaging is 2000 pieces per carton, distributed into 8 inner PE bags with 250 pieces inside each. Each bag is sealed separately with protective cushioning to prevent damage.