Our suction filters are designed to serve as a crucial barrier that protects sensitive components of suction devices from bodily fluids. Manufactured in China, our filters feature a high-quality hydrophobic PTFE (polytetrafluoroethylene) membrane that ensures optimal performance. With a 0.2µm two-sided PTFE membrane, our filters offer an exceptional filtration solution that efficiently captures particles while safeguarding against liquid contamination. This design not only enhances protection but also allows for essential air circulation in various hospital suction systems. As a leading supplier and factory in the industry, we are committed to delivering high-performance filtration solutions tailored to your needs

    Product Introduction

    Suction devices, which are frequently used in medical and healthcare settings, are susceptible to damage and contamination when they come into contact with bodily fluids. This susceptibility can compromise their functionality and pose significant health risks. To mitigate these issues, a suction filter is commonly used and placed between the suction pump and the secretion canister to prevent bacterial/viral and particulate contaminate from entering hospital suction system or equipment. A suction filter generally consists of two housings sealed around a filtering hydrophobic membrane, and the effectiveness of a suction filter to act as such a sterile barrier mainly depends on its key component: the hydrophobic PTFE (polytetrafluoroethylene) membrane built into the filter. Our custom-made 0.2-micron PTFE membrane is an ideal material for this application because it possesses several properties that make it exceptionally well-suited for this medical use.
    To achieve optimal performance, the custom designed binder-free PTFE membrane features two-side hydrophobic PTFE material, which means both faces of the membrane are PTFE, with exactly the same physical properties and high performance, making both faces suitable for being used as working face and reducing assembly mistakes. This PTFE laminated membrane filter is reinforced and durable with a maximum service-life of 24 hours and meets various operating conditions. Easy and convenient for further processing and assembly, available in roll and precut circle forms.
    Furthermore, PTFE material is highly hydrophobic, meaning it repels water and other liquids. Our PTFE membrane filter is designed, tested and processed so that it ensures that bodily fluids cannot penetrate the membrane under operation pressure of various suction systems, thereby protecting the internal components of the suction device from contamination and minimize significant health risks. Besides, PTFE is chemically inert, which means it does not react with or degrade when exposed to various chemicals commonly presenting in bodily fluids.
    In addition, the specially crafted microporous structure of our 0.2μm PTFE membrane allows adequate airflow to pass through while effectively blocking liquids, bacteria, aerosolized particles and other microorganisms with 99.9% efficiency, preventing any potential introduction of harmful contaminants into the suction system, reducing the risk of infections that could compromise patient health or equipment functionality.
    By integrating these two functions—effective liquid barrier protection and necessary airflow, the dual-layer PTFE membrane filter from us could support suction filter manufacturers who consider patient safety as highest priority to achieve their goal more easily, and more cost-wise.

    Features

    • Two-side of 0.2-micron PTFE
    • Bacterial retentive
    • Naturally hydrophobic
    • Broad chemical compatibility
    • High and stable air flow rate
    • Liquid barrier with high WBT pressure rating
    • High biosafety level
    • 100,000 grade cleanrooms manufactured
    • 100% Inspection
    PTFE membrane for medical suction filters 900 X 600

    Specifications

    Property Specification Details
    Material PTFE-PP/PTFE-PET
    Thickness 250μm, 400μm or custom
    Pore size 0.2μm
    Air flow rate ≥25ml/min@5kpa
    Water Break Through ≥3.0bar (43.5psi)
    Applications
    The two-side hydrophobic PTFE membrane filter is designed and manufactured in such a way that they can be used safely in many medical filter devices that would require a filtering hydrophobic membrane to act as a sterile barrier, including but not limited to:
    • Suction filters
    • Transducer protectors
    • EtCO2 filters (Capno Sampling Line Filter)
    • Bacterial filters
    • Medical breathing filters
    • Ventilator filters for breathing systems
    • Single-use vent filters
    Warnings
    • Handle with care to avoid damaging the filter material.
    • Sterilization by irradiation is not recommended.
    • Do not use glue or cyclohexanone for joining with housing as it will clog the material itself, preventing gas from passing through.
    • Avoid contact with alcohol or highly permeable solvents, otherwise, the material will become hydrophilic before it fully dries.

    Ordering Information

    Material Ref. Pore Size Thickness Membrane Size Lot No.
    PTFEp 022 025 Custom -

    Frequently Asked Questions (FAQ)

    What is the function of a PTFE membrane in medical suction filters?
    The PTFE membrane acts as a reliable sterile barrier. It prevents bacterial, viral, and particulate contamination from entering hospital suction systems or equipment while ensuring sufficient airflow.
    What are the benefits of a two-sided hydrophobic PTFE membrane?
    Both faces of the membrane feature identical physical properties and high performance. This allows either side to be used as the working face, simplifying assembly and reducing manufacturing errors.
    What is the filtration efficiency and pore size of this membrane?
    The membrane has a 0.2μm microporous structure that blocks liquids, bacteria, aerosolized particles, and microorganisms with a 99.9% efficiency rating.
    How long is the service life of this PTFE membrane filter?
    This reinforced and durable PTFE laminated membrane filter is designed to support a maximum service life of up to 24 hours under various operating conditions.
    Are there specific warnings regarding assembly and sterilization?
    Yes. Do not use glue or cyclohexanone for joining as they will clog the membrane. Sterilization by irradiation is not recommended, and contact with alcohol or highly permeable solvents should be avoided to prevent loss of hydrophobicity.