Featured sterile medical membranes and in-line venting assemblies designed to optimize air bubble evacuation, maintain flow dynamics, and eliminate clinical vascular risks.
Navigating the complex physiological hazards of vascular gas accumulation and technical membrane mechanics in modern infusion therapy.
In-line intravenous (IV) filtration devices operate on an interdependent balance between hydrophilic liquid filtration membranes (such as PES) and hydrophobic venting membranes (typically ePTFE). As aqueous solution primes the chamber, the hydrophilic membrane wets spontaneously while the hydrophobic membrane remains dry and impervious to liquid. Entrained microbubbles and ambient air pocketing travel ahead of or with the fluid column, contacting the hydrophobic pores and venting freely into the environment. Once all air escapes, the fluid column forms a continuous liquid bridge, terminating gas transmission and averting downstream air embolism.
In contemporary parenteral therapeutics, intravenous infusion represents one of the most widely administered clinical protocols worldwide. However, the presence of entrained gas within administration sets poses profound risks. Air can be introduced during bag spikes, secondary piggyback changes, medication reconstitution, temperature-induced outgassing of dissolved ambient air, or through microscopic fissures in tubing connectors. Even micro-bubbles smaller than 50 microns, when infused cumulatively, can aggregate in the microvasculature, leading to pulmonary microvascular occlusions, cerebral micro-strokes (especially in patients with patent foramen ovale), and localized tissue ischemia.
Consequently, modern regulatory bodies such as the FDA, EMA, and ISO (notably under ISO 8536-4 and ISO 8536-8 frameworks) emphasize the integration of certified air-eliminating filters. IV filters venting mechanisms act as fail-safe passive barriers. When an infusion run empties, the venting membrane rapidly equilibrates the pressure differential, allowing the hydrophilic membrane to dry-lock due to its intrinsic bubble point rating. This dry-lock mechanism arrests fluid flow instantaneously, preventing gravity or pump-driven column collapse from pumping catastrophic volumes of air directly into the venous stream.
Historically, standard hydrophobic polytetrafluoroethylene (ePTFE) membranes sufficed for conventional crystalloid infusions such as 0.9% Normal Saline or 5% Dextrose. However, modern pharmaceutical administration frequently involves lipophilic drug formulations, total parenteral nutrition (TPN) lipid emulsions, and oncology chemotherapeutic agents suspended with synthetic non-ionic surfactants such as Polysorbate 80 (Tween 80) and Cremophor EL.
These low-surface-tension additives dramatically reduce the surface tension of the fluid column from approximately 72 dynes/cm (pure water) to well below 30 dynes/cm. When a low-surface-tension liquid encounters a conventional hydrophobic membrane, the liquid can wet-out the pores—a phenomenon known as membrane breach or wetting failure. When a vent wets out, air venting ceases entirely, fluid leaks through the vents, and sterile containment is compromised.
To counteract this industrial challenge, advanced fluoropolymer chemical modifications have yielded oleophobic ePTFE membranes. By applying proprietary fluorochemical surface grafting without compromising the interconnected microporous fibril matrix, these membranes achieve oil-repellency ratings (AATCC 118) of Grade 7 to 8. This guarantees that intravenous lipids and alcohol-formulated taxane drugs pass cleanly across the hydrophilic PES channel while leaving the oleophobic air vent intact, functional, and fully dry throughout extended 24- to 96-hour infusion regimens.
Decades of membrane innovation backed by rigorous international quality compliance.
As a high-tech enterprise integrating research and development, production, and sales, we provide a wide assortment of membranes with different performance characteristics, making it easy for you to find the membrane that exactly fits your application. In addition, we have more than 30 years of extensive membrane manufacturing experience and deep expertise in related regulatory compliance, in cases where the available membranes or devices are not ideal for your application, our sales and R&D team will work closely with you to create tailormade and reliable solutions to meet your specific application requirements.
The extensive collection of microporous filter medium and devices we provide are specifically designed and optimized for various medical and healthcare applications, such as for infusion therapy, drug delivery and transfer, and medical equipment protection. The microporous filter materials are manufactured under highly controlled conditions with quality systems certified to ISO 9001. Among our 161,458 square feet manufacturing facilites, 75,347 square feet are Class 100,000 cleanroom. This clean production environment enables us to provide customers with higher levels of cleanliness and contamination-free product status.
High performing and affordable filtration materials and devices for medical device manufacturers and healthcare professionals.

Hydrophilic membranes are suitable for filtering aqueous solutions, retaining larger particulates and reducing the risk of bacterial contamination during IV drug preparation. Engineered with high flow rates and ultra-low extractables for superior biocompatibility.
Explore Our Products
Hydrophobic membranes manufactured of advanced microporous materials, to be used as components of medical and healthcare devices for venting, gas equilibration, bacterial barrier retention, and aerosol isolation.
Explore Our Products
XINNA carries a broad range of trusted healthcare filters, accessories and consumables, such as IV filters, Bacterial air vents, TP filter, transfer spikes and more. Our most iconic products are IV filters, integrating these micron filters into IV tubing sets helps to remove air from the line and retain bacteria, endotoxins, and particulate matter, significantly decreasing patient risks during complex therapy cycles.
Specialized clinical implementations of high-performance venting and fluid filtration barriers.
Manufactured according to ISO standards, a wide assortment of membranes with different performance characteristics, making it easy for you to find the best membrane to fit your application. Extensive membrane manufacturing experience with advanced device engineering and deep expertise to create tailormade solutions to your specific application needs.
Manufactured according to ISO standards, filter of choice for Fortune 500 medical device manufacturers. 0.22 micron Hydrophobic membrane which allows only sterile air to pass through and prevents blood and dialyzing fluid from damaging sensitive transducers. With such a filter media built-in, transducer protectors or in short TP filters are widely used in Hemodialysis blood lines to protect both the patients and dialysis equipment from cross contamination.
Manufactured according to ISO standards, integrated with high quality hydrophobic bacterial filter media which could effectively prevent bacterium, moisture and secretions from entering the line while maintaining laminar flow and excellent waveforms. These filter devices are available with 0.22μm pore size PTFE membranes, medical grade safe ABS housing, and luer lock connector which enables easy connection.
Single-use transfer devices that aim to make withdrawal and addition of medications easy & safe. These admixture devices are ideal for reconstituting and admixing drugs enabling the transfer of fluids from a drug vial to an IV bag safely, efficiently and without any waste. Compatible with all types of 50, 100, and 250 mL IV bags, suitable for use with liquid and powder medications. The vented models with air filter provides an additional protection against toxic aerosols during the preparation of drugs and reduces the bacterial contamination risk during the fluid transfer.
A full array of ISO-compliant microporous membranes, IV in-line filters, and vented transfer components.
Our technical and customer support teams always focus on the needs and satisfaction of our customer and are able and flexible to provide, optimize or develop products to solve your challenging filtration issues. It’s been our constant commitment to supporting our customers with products that meet both their budget and performance expectations, and to doing our part effectively to speed up the launch time of customer’s finished products to market.
Consult an OEM Membrane Engineer