Engineered to satisfy stringent clinical infusion protocols with advanced degassing and biocompatible fluid conduits.
Comprehensive biological defense mechanisms against micro-particulates, phlebitis, systemic infection, and air embolism risks.
Intercepts glass fragments from snapped ampoules, undissolved lyophilized drug precipitates, and rubber vial core slivers.
0.2 μm retention blocks *Pseudomonas aeruginosa*, *Staphylococcus aureus*, and fungal spores from entering bloodstreams.
Integrated hydrophobic PTFE vents release entrained micro-air bubbles continuously, preventing microvascular pulmonary embolisms.
In contemporary hospital intensive care units (ICUs), surgical theaters, and pediatric wards, intravenous (IV) infusion therapy represents the primary vascular conduit for life-saving therapeutics, fluid replenishment, hemodynamic stabilization, and critical nutritional delivery. However, the vascular lumen remains exceptionally vulnerable to foreign physical contaminants. When medical solutions are reconstituted and compounded from glass ampoules or rubber-stoppered vials, microscopic glass shards, elastomeric fragments, and chemical aggregates inadvertently breach the fluid path. Clinical histology indicates that sub-visible particles (ranging from 2 μm to 50 μm) cause microvascular endothelial lesions, trigger localized platelet aggregation, and provoke foreign-body granulomas in pulmonary, hepatic, and renal capillary beds.
The insertion of an inline IV filter directly into the administration line serves as an absolute physiological gatekeeper. By implementing membrane pore thresholds tailored to the clinical solute—specifically 0.22 μm for crystalline aqueous infusions and 1.2 μm for high-molecular lipid parenteral admixtures—clinicians effectively eradicate particle-induced infusion phlebitis. Multi-center clinical studies demonstrate that inline filtration reduces peripheral infusion phlebitis by up to 68%, diminishes systemic inflammatory response syndrome (SIRS) manifestations in critically ill patients, and prevents catastrophic line occlusions during polypharmacy infusions.
Entrained air within IV tubing constitutes a silent, ubiquitous hazard in clinical workflows. Micro-bubbles inevitably generate during solution degassing, temperature equilibration, rapid pressure infusions, or secondary line changeovers. When introduced into central venous access devices or arterial lines, micro-bubbles can coalesce, causing focal ischemia or paradoxical air embolisms through a patent foramen ovale (PFO). Advanced inline IV filters overcome this physiological threat via dual-membrane bi-functional architecture. Hydrophilic polyethersulfone (PES) membranes permit effortless aqueous flow under standard gravity and peristaltic pump pressures while remaining impervious to gas when wetted. Concurrently, multi-quadrant hydrophobic venting membranes constructed of expanded polytetrafluoroethylene (ePTFE) provide low-surface-energy conduits that vent trapped gases instantaneously into ambient atmosphere without liquid leaking or microbial ingress.
Surpassing ISO, USP, and Medical Device Regulation (EU MDR) benchmarks for fluid pathway safety.
Infusion filters encounter hostile biochemical environments, ranging from highly alkaline antibiotic admixtures to surfactant-rich oncological taxanes and lipidic carrier systems. Consequently, medical-grade inline filters must demonstrate absolute chemical inertness. The structural housing—traditionally molded from clear, radiation-stable acrylics, modified polymethyl methacrylate (PMMA), or medical-grade polypropylene—must conform rigorously to ISO 10993 standards for cytotoxicity, systemic toxicity, intracutaneous reactivity, and hemocompatibility.
Furthermore, raw membrane chemistry must mitigate non-specific drug adsorption. Standard polyethersulfone (PES) membranes intended for hospital infusion are hydrophilic-modified to present neutral or slightly negative surface charges, ensuring negligible binding affinity with low-dose active pharmaceutical ingredients (APIs) such as biologics, monoclonal antibodies (mAbs), and vasoactive inotropes. In total parenteral nutrition (TPN) regimes containing emulsified long-chain triglycerides, membrane surface energy is customized to resist oleophobic fouling and preserve constant volumetric flow rates over protracted 24- to 96-hour continuous clinical runs.
Global regulatory agencies, including the US Food and Drug Administration (FDA) and European Notified Bodies operating under the EU Medical Device Regulation (MDR 2017/745), hold inline IV filters to strict quality paradigms. The filtration media must meet the stringent particulate limits specified under United States Pharmacopeia (USP) <788> for Particulate Matter in Injections. Inline IV filters must withstand operational pressures exceeding 2 to 3 bar to safely withstand modern electronic volumetric infusion pump overpressures without membrane rupture, seal delamination, or structural micro-cracking.
As a high-tech enterprise integrating research and development, production, and sales, we provide a wide assortment of membranes with different performance characteristics, making it easy for you to find the membrane that exactly fits your application. In addition, we have more than 30 years of extensive membrane manufacturing experience and deep expertise in related regulatory compliance, in cases where the available membranes or devices are not ideal for your application, our sales and R&D team will work closely with you to create tailormade and reliable solutions to meet your specific application requirements.
The extensive collection of microporous filter medium and devices we provide are specifically designed and optimized for various medical and healthcare applications, such as for infusion therapy, drug delivery and transfer, and medical equipment protection. The microporous filter materials are manufactured under highly controlled conditions with quality systems certified to ISO 9001. Among our 161,458 square feet manufacturing facilites, 75,347 square feet are Class 100,000 cleanroom. This clean production environment enables us to provide customers with higher levels of cleanliness and contamination-free product status.
Targeted filtration solutions engineered for vulnerable patient populations and complex pharmacology.
Manufactured according to ISO standards, a wide assortment of membranes with different performance characteristics, making it easy for you to find the best membrane to fit your application. Extensive membrane manufacturing experience with advanced device engineering and deep expertise to create tailormade solutions to your specific application needs.
Neonatal and Pediatric Intensive Care (NICU/PICU): Neonatal patients exhibit low circulating blood volume, narrow microvascular diameters, and underdeveloped reticuloendothelial filter systems. The systemic entry of minute particles or trace air bubbles can cause severe complications, including cerebral micro-infarctions and pulmonary vascular hyper-reactivity. Utilizing our specialized 0.2 μm PES low-priming-volume inline IV filters ensures total particulate exclusion and continuous degassing without fluid retention, safeguarding neonates undergoing hyperalimentation or inotropic support.
Manufactured according to ISO standards, filter of choice for Fortune 500 medical device manufacturers. 0.22 micron Hydrophobic membrane which allows only sterile air to pass through and prevents blood and dialyzing fluid from damaging sensitive transducers. With such a filter media built-in, transducer protectors or in short TP filters are widely used in Hemodialysis blood lines to protect both the patients and dialysis equipment from cross contamination.
Manufactured according to ISO standards, integrated with high quality hydrophobic bacterial filter media which could effectively prevent bacterium, moisture and secretions from entering the line while maintaining laminar flow and excellent waveforms. These filter devices are available with 0.22μm pore size PTFE membranes, medical grade safe ABS housing, and luer lock connector which enables easy connection.
Single-use transfer devices that aim to make withdrawal and addition of medications easy & safe. These admixture devices are ideal for reconstituting and admixing drugs enabling the transfer of fluids from a drug vial to an IV bag safely, efficiently and without any waste. Compatible with all types of 50, 100, and 250 mL IV bags, suitable for use with liquid and powder medications. The vented models with air filter provides an additional protection against toxic aerosols during the preparation of drugs and reduces the bacterial contamination risk during the fluid transfer.
Comprehensive portfolio protecting critical fluid paths across institutional health systems.




High performing and affordable filtration materials and devices for medical device manufacturers and healthcare professionals.

Hydrophilic membranes are suitable for filtering aqueous solutions, retaining larger particulates and reducing the risk of bacterial contamination during IV drug preparation...
Explore Our Products
Hydrophobic membranes manufactured of advanced microporous materials, to be used as components of medical and healthcare devices for venting, gas...
Explore Our ProductsPioneering smart inline sensing, positive charge endotoxin retention, and ultra-low binding polymer matrices.
While standard 0.22 μm sterilizing-grade hydrophilic membranes reliably retain bacterial cells such as *Burkholderia cepacia*, dead gram-negative bacteria can lyse and release bacterial lipopolysaccharides (endotoxins). Unfiltered endotoxins passing into vascular access trigger cytokine release, causing drug-induced fever, severe hypotension, and septic shock symptoms. Next-generation inline IV filters integrate cross-linked cationic quaternary amine polymer chemistries onto the microporous PES structure. This engineering breakthrough creates an electropositive matrix that physically adsorbs and binds negatively charged endotoxins through electrostatic interaction, providing an extra layer of clinical protection during prolonged multi-day infusions.
In antineoplastic regimens, cytotoxic drugs (e.g., paclitaxel, cisplatin, fluorouracil) are notorious for micro-crystallization and precipitation when mixed with electrolytes or subjected to temperature fluctuations. Furthermore, clinical oncology staff face acute occupational risks from aerosolized cytotoxic droplets during system priming and venting. Modern enclosed inline filter housings incorporate auto-priming hydrophilic discs alongside non-wettable PTFE venting plugs, ensuring that hazardous antineoplastic solutions are filtered without toxic aerosol release into the compounding cleanroom or bedside nursing station.
The forward trajectory of hospital infusion technology converges on closed IV catheter systems and closed system drug-transfer devices (CSTDs). Future inline filters are moving toward seamless integration with smart infusion pumps, featuring embedded miniaturized micro-transducers that detect upstream pressure elevation indicative of drug precipitation or filter saturation. Such predictive real-time telemetry informs nursing teams prior to complete line occlusion, facilitating proactive replacement and ensuring uninterrupted administration of short-half-life vasoactive medications.
Our technical and customer support teams always focus on the needs and satisfaction of our customer and are able and flexible to provide, optimize or develop products to solve your challenging filtration issues. It's been our constant commitment to supporting our customers with products that meet both their budget and performance expectations, and to doing our part effectively to speed up the launch time of customer's finished products to market.
Comprehensive portfolio of sterile barrier membranes, transducer guards, IV vents, and transfer systems.