Hydrophobic PTFE Transducer Protector Filter - China Suppliers & Factory for Sterilization and Particle Removal
Hot Products

Hydrophobic PTFE Transducer Protector Filter - China Suppliers & Factory for Sterilization and Particle Removal

Category: T
Filter Media: Hydrophobic PTFE
Housing Material: Durable ABS-based polymers
Particle Removal Options: Available in 0.22μm, 0.45μm, and 1.0μm
Sterilization Method: Ethylene oxide (Maximum temperature 60°C)
Standards Compliance: GB/T1962.2-2001, ISO 594-2, adhering to ISO 9001 quality standards
China Suppliers and Factory: As a leading manufacturer in China, we provide high-quality filtration solutions that meet international standards.

    Product Introduction

    Transducer Protector Filter with hydrophobic PTFE membrane (0.22/0.45/1.0μm) in an ABS-based polymers housing. Non-toxic, non-sterile. The product is provided for further manufacturing, processing and repackaging. PTFE filter membranes adopt a dual-layer lamination design, which offers more comprehensive filtration effects. Air entering from any direction is effectively treated with antibacterial filtration while ensuring venting. Hemodialysis machine's circuits are equipped with Transducer Protectors Filters (TP filters) to protect the equipment sensor and reduce the risk of infection control to some extent.

    Features

    • Equipped hydrophobic PTFE
    • Antibacterial and air venting
    • Allows only sterile air to pass through
    • Protect patients and equipment from both bacterial and viral cross-contamination
    • Eliminates contamination of the internal pressure monitoring lines
    • Prevents blood and dialyzing fluid from damaging sensitive transducers
    TP filter in hemodialysis

    Specifications

    Dimensions 25.5*21.2mm (Luer connector included)
    Connector Luer lock connector compatible with GB/T 1962.2-2001 (ISO 594-2)
    Max burst pressure 4.0bar (58.0 psi)
    Venting area 1.13cm²
    Operating temp 10-30℃
    Pyrogenicity ≤0.5EU/PC
    Storage temp 5-40℃
    Sterilization Ethylene oxide (Max 60℃)

    Performance

    TP Venting Flow Rate Chart

    Applications

    Hemodialysis

    Transducer protectors filters are used in hemodialysis blood lines, one each for arterial and venous pressures. TP filters with hydrophobic filtration membranes can separate the liquid (priming fluid, blood) in the circuit from the transducer, preventing the blood flowing through the circuit from contaminating the machine.

    In-line air venting filter for Intensive Care Unit

    Transducer protector filters guarantee a sufficient air flow to provide immediate reaction time if there is a change in patient blood pressure.

    Package

    • 6000pcs/box, 3 inner PE bags with 2000 pcs inside each. Each bag is sealed separately and cushioned between each other.
    • Each bag is labeled with detailed information. Different lots in one box are closed separately and labeled separately to prevent mix up.

    Labeled Information

    Name Model Specifications Quantity Batch no. Operator no.

    Warnings

    Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
    Handle with care.
    Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visibly or invisibly.
    It's not recommended to use alcohol or any kind of disinfectant in direct contact with filter media; PTFE membrane will become hydrophilic until dried.

    Ordering Information

    Appearance Housing Filter Media Options Mold Connection Vents
    GLXL 012 022 T 2Y N
    GLXY - 045 - - -
    GLXY - 100 - - -

    Frequently Asked Questions (FAQ)

    What is the primary function of the Transducer Protector Filter?
    The Transducer Protector Filter is designed to protect equipment sensors and pressure monitoring lines in hemodialysis machines. It acts as a barrier that prevents blood and dialyzing fluid from contaminating the internal components, thereby reducing the risk of cross-contamination.
    What materials are used to manufacture these filters?
    The filter is constructed with a hydrophobic PTFE membrane (available in 0.22μm, 0.45μm, and 1.0μm pore sizes) housed in an ABS-based polymer casing.
    Can I use alcohol to clean or disinfect the filter housing?
    No, alcohol must not come into contact with the housing, as it will cause visible or invisible damage to the ABS-based polymer structure. Additionally, alcohol should not contact the PTFE membrane directly, as it will temporarily render the membrane hydrophilic.
    How are the filters packaged and labeled?
    They are packed with 6000 pieces per box, divided into 3 sealed inner PE bags containing 2000 pieces each. Each bag is labeled individually with the product Name, Model, Specifications, Quantity, Batch number, and Operator number to prevent mix-ups.
    What are the recommended temperature limits for storage and operation?
    The recommended operating temperature range is between 10°C and 30°C. For storage, the temperature should be maintained between 5°C and 40°C.
    Are these filters delivered sterile?
    No, the product is provided non-sterile and is intended for further manufacturing, processing, and repackaging. They are compatible with Ethylene Oxide (EO) sterilization up to a maximum temperature of 60°C.