Leave Your Message
Hydrophobic PTFE Transducer Protector Filter - China Suppliers Factory | 0.22/0.45/1.0μm Removal, Sterilization & Compliance
Hot Products

Hydrophobic PTFE Transducer Protector Filter - China Suppliers Factory | 0.22/0.45/1.0μm Removal, Sterilization & Compliance

Category: T
Filter Media: Hydrophobic PTFE
Housing: Made from durable ABS-based polymers
Removal of Particles options: Available in 0.22/0.45/1.0μm
Sterilization: Ethylene oxide (Max 60℃)
Standard: Compliant with GB/T1962.2-2001 and ISO 594-2, following ISO9001 quality standards

Our factory in China manufactures high-quality filter solutions with hydrophobic PTFE media, ideal for various applications. As a leading supplier, we offer a range of particle removal options to meet your needs, ensuring compliance with stringent international standards. Contact us today to discover our products and experience the reliability of our filters directly from a trusted Chinese manufacturer.

    Product Introduction

    Transducer Protector Filter with hydrophobic PTFE membrane (0.22 / 0.45 / 1.0μm) in an ABS-based polymers housing. Non-toxic, non-sterile. The product is provided for further manufacturing, processing and repackaging. PTFE filter membranes adopt a dual-layer lamination design, which offers more comprehensive filtration effects. Air entering from any direction is effectively treated with antibacterial filtration while ensuring venting. Hemodialysis machine's circuits are equipped with Transducer Protectors Filters (TP filters) to protect the equipment sensor and reduce the risk of infection control to some extent.

    Features

    • Equipped hydrophobic PTFE
    • Antibacterial and air venting
    • Allows only sterile air to pass through
    • Protect patients and equipment from both bacterial and viral cross-contamination
    • Eliminates contamination of the internal pressure monitoring lines
    • Prevents blood and dialyzing fluid from damaging sensitive transducers
    TP filter in hemodialysis - 2u7y

    Specifications

    Dimensions 25.5*21.2mm (Luer connector included)
    Connector Luer lock connector compatible with GB/T 1962.2-2001 (ISO 594-2)
    Max burst pressure 4.0bar (58.0 psi)
    Venting area 1.13cm²
    Operating temp 10-30℃
    Pyrogenicity ≤0.5EU/PC
    Storage temp 5-40℃
    Sterilization Ethylene oxide (Max 60℃)

    Performance

    tp-ventww8

    Applications

    Hemodialysis

    Transducer protectors filters are used in hemodialysis blood lines, one each for arterial and venous pressures. TP filters with hydrophobic filtration membranes can separate the liquid (priming fluid, blood) in the circuit from the transducer, preventing the blood flowing through the circuit from contaminating the machine.

    In-line air venting filter for Intensive Care Unit

    Transducer protector filters guarantee a sufficient air flow to provide immediate reaction time if there is a change in patient blood pressure.

    Package

    • 6000pcs/box, 3 inner PE bags with 2000 pcs inside each. Each bag is sealed separately and cushioned between each other.
    • Each bag is labeled with information as following; different lots in one box are closed separately and labeled separately to prevent mix up.

    Labeled Information

    Name Model Specifications Quantity Batch no. Operator no.

    Warnings

    Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
    Handle with care.
    Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
    It's not recommended to use alcohol or any kind of disinfectant in direct contact with filter media, PTFE membrane will become hydrophilic until dried.

    Ordering Information

    Appearance Housing Filter media options Mold Connection Vents
    GLXL 012 022 T 2Y N
    GLXY - 045 - - -
    GLXY - 100 - - -

    Frequently Asked Questions (FAQ)

    What is the primary function of a Transducer Protector Filter in hemodialysis?

    Transducer Protector Filters (TP filters) are installed in hemodialysis blood lines to protect internal pressure transducers from fluid contamination, prevent blood and dialyzing fluid from damaging sensitive equipment, and eliminate cross-contamination risks.

    What filter media and pore sizes are available for this TP filter?

    The filter features a hydrophobic PTFE membrane with a dual-layer lamination design. It is available in three pore size options: 0.22μm, 0.45μm, and 1.0μm.

    Is the connector compatible with international standard Luer fittings?

    Yes, the filter is equipped with a standard Luer lock connector compatible with GB/T 1962.2-2001 and ISO 594-2 standards.

    Why should alcohol be avoided when handling or cleaning the filter housing?

    Direct contact with alcohol can damage the ABS-based housing (both visible and invisible damage). Additionally, alcohol contacts with the PTFE membrane may cause it to temporarily become hydrophilic until completely dry.

    What sterilization method is suitable for these transducer protectors?

    The filters are supplied non-sterile for further manufacturing and repackaging, and are compatible with Ethylene Oxide (EtO) sterilization up to a maximum temperature of 60°C.

    How are the filters packaged to prevent lot mix-ups?

    Products are packaged with 6,000 pcs per master box, containing 3 individually sealed inner PE bags (2,000 pcs each) with protective cushioning. Different lots within a box are closed and labeled separately with Name, Model, Specifications, Quantity, Batch No., and Operator No.