Leave Your Message
Hydrophobic PTFE Transducer Protector Filter - China Suppliers and Factory for Reliable Filtration Solutions
Hot Products

Hydrophobic PTFE Transducer Protector Filter - China Suppliers and Factory for Reliable Filtration Solutions

Category: T
Filter Media: Hydrophobic PTFE
Housing: Durable ABS-based polymers
Particle Removal Options: Available in 0.22/0.45/1.0μm
Sterilization Method: Ethylene oxide (Max temperature 60℃)
Standards Compliance: Meets GB/T1962.2-2001 and ISO 594-2, certified under ISO9001 for quality assurance.
As a leading supplier and factory in China, we specialize in high-performance filtration solutions designed to meet stringent industry standards. Our innovative products guarantee exceptional particle removal and reliability for all applications.

    Product Introduction

    Transducer Protector Filter with hydrophobic PTFE membrane (0.22/0.45/1.0μm) in an ABS-based polymers housing. Non-toxic, non-sterile. The product is provided for further manufacturing, processing and repackaging. PTFE filter membranes adopt a dual-layer lamination design, which offers more comprehensive filtration effects. Air entering from any direction is effectively treated with antibacterial filtration while ensuring venting. Hemodialysis machine's circuits are equipped with Transducer Protectors Filters (TP filters) to protect the equipment sensor and reduce the risk of infection control to some extent.

    Features

    • Equipped hydrophobic PTFE
    • Antibacterial and air venting
    • Allows only sterile air to pass through
    • Protect patients and equipment from both bacterial and viral cross-contamination
    • Eliminates contamination of the internal pressure monitoring lines
    • Prevents blood and dialyzing fluid from damaging sensitive transducers
    TP filter in hemodialysis - 2u7y

    Specifications

    Parameter Specification Details
    Dimensions 25.5*21.2mm (Luer connector included)
    Connector Luer lock connector compatible with GB/T 1962.2-2001 (ISO 594-2)
    Max Burst Pressure 4.0bar (58.0 psi)
    Venting Area 1.13cm²
    Operating Temp 10 - 30℃
    Pyrogenicity ≤0.5EU/PC
    Storage Temp 5 - 40℃
    Sterilization Ethylene oxide (Max 60℃)

    Performance

    tp-ventww8

    Applications

    Hemodialysis

    Transducer protectors filters are used in hemodialysis blood lines, one each for arterial and venous pressures. TP filters with hydrophobic filtration membranes can separate the liquid (priming fluid, blood) in the circuit from the transducer, preventing the blood flowing through the circuit from contaminating the machine.

    In-line Air Venting Filter for ICU

    Transducer protector filters guarantee a sufficient air flow to provide immediate reaction time if there is a change in patient blood pressure.

    Package & Labeled Information

    • Quantity: 6000pcs/box, 3 inner PE bags with 2000 pcs inside each.
    • Sealing: Each bag is sealed separately and cushioned between each other.
    • Traceability: Different lots in one box are closed and labeled separately to prevent mix up.
    Each bag is labeled with:
    Name Model Specifications Quantity Batch No. Operator No.
    Warnings
    • Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
    • Handle with care.
    • Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visibly or invisibly.
    • It's not recommended to use alcohol or any kind of disinfectant in direct contact with filter media. PTFE membrane will become hydrophilic until dried.

    Ordering Information

    Appearance Housing Filter Media Options Mold Connection Vents
    GLXL 012 022 T 2Y N
    GLXY - 045 - - -
    GLXY - 100 - - -

    Frequently Asked Questions (FAQ)

    Q1: What is the main function of the Transducer Protector Filter?
    The Transducer Protector Filter (TP filter) is designed to protect the equipment sensor in hemodialysis machine circuits and reduce the risk of cross-contamination by preventing blood and dialyzing fluid from damaging sensitive transducers.
    Q2: What materials are used in the construction of the filter?
    It features a hydrophobic PTFE membrane (available in 0.22µm, 0.45µm, and 1.0µm pore sizes) housed in an ABS-based polymer casing. The PTFE membrane uses a dual-layer lamination design for comprehensive filtration.
    Q3: Can alcohol be used to clean or disinfect the filter housing?
    No, alcohol must not come into contact with the housing, as it can cause visible or invisible damage to the ABS-based polymer. Additionally, alcohol will make the hydrophobic PTFE membrane hydrophilic until it is completely dried.
    Q4: How is this product packaged and labeled?
    It is packaged with 6000 pieces per box, split into 3 inner PE bags of 2000 pieces each. Each bag is sealed individually and cushioned. Labels include Name, Model, Specifications, Quantity, Batch number, and Operator number.
    Q5: What are the recommended storage and sterilization parameters?
    The filter should be stored between 5 - 40℃, and operated within 10 - 30℃. It is compatible with Ethylene Oxide (EO) sterilization up to a maximum temperature of 60℃.