Leave Your Message
Hydrophobic Membrane for Venting Caps & Priming Filters - Top China Suppliers & Factory Products
Hot Products

Hydrophobic Membrane for Venting Caps & Priming Filters - Top China Suppliers & Factory Products

Our hydrophobic microporous membrane, made of high-quality PTFE, is a leading choice among medical suppliers in China. Renowned for its outstanding chemical stability and hydrophobic properties, this membrane offers essential advantages in the medical field. Its unique characteristics effectively prevent liquid penetration while allowing for optimal air flow, making it ideal for breathable medical accessories that require both high breathability and waterproof features. Choose our factory for reliable and innovative solutions in medical membrane technology

    Product Introduction

    We choose Hydrophobic PTFE membrane which is wide used filter media for medical air vents, closing caps, priming filters. It is a high-end micro porous material which possesses natural hydrophobicity and broad chemical compatibility. Which as part of IV set: closing caps, priming filters with PTFE membrane is a venting device whose main function is covering the distal end of the intravenous (IV) line, which is not attached to a catheter or a needle.
    To be an air vent: air elimination is an important feature, it prevents the flow and spillage of the intravenous fluid to the outside environment. But allows the passage of air that has been entrapped in the intravenous line or tubing.
    Air flow key performance indicator that should be considered when choosing a venting membrane.
    Our biaxially stretched PTFE venting membrane has wide options of substrates of non-woven materials to ensure material compatibility between the membrane and its housing, also guarantee welding integrity.
    Working with us, you can expect tailored membrane solutions to satisfy your complicated applications and functional demand. The expanded structure of PTFE itself allows a range of customized options of pore sides to meet various requirements on airflow rate and bacteria or particulate filtration.

    Features

    • Naturally Hydrophobic and wide Chemical compatibility
    • With medical-class PET or PP support
    • High air flow (depends on the filtration area and pore size of the membrane)
    • Great performance on air elimination
    • Excellent mechanical strength
    • Anti-bacterial (depends on the pore size of the membrane)
    • Good welding strength
    vented caps priming caps

    Specifications

    Specification Details
    Material PTFE-PP/PTFE-PET
    Thickness Customizable
    Pore size 0.22μm/0.45μm/1.2μm
    WBT 0.22μm:200Kpa@15min; 0.45μm:150Kpa@15min; 1.2μm:60Kpa@15min
    Air Flow (mL/cm2/min) 0.22μm:300; 0.45μm: 700; 1.2μm: 2300
    Endotoxin <0.5EU/ml

    Performance

    venting cap's PTFE

    Applications

    Air venting Closing caps Priming filters Gas filtration TSP ambient air monitoring Bacterial isolation
    Closing caps which is also called priming caps are equipped on the infusion set end , have strict requirements for breathability and waterproofness, even bacterial resistance during use. XINNA PTFE membrane with pore size 0.22/0.45/1.2μm perfectly solve these problems, achieving a dual effect of breathability and protection.
    This material has long-term durability to meet various working conditions. We can provide rolls ,sheets or discs.
    Warning / Handling Precautions
    • Handle with care to avoid damaging the filter material.
    • Sterilization by irradiation is not available.
    • Do not use glue or cyclohexanone for adhesion as it can clog the material itself, preventing gas from passing through.
    • Avoid contact with alcohol or high-permeability solvents, otherwise, the material will become hydrophilic before it is fully dried.

    Ordering Information

    Material Pore Size Thickness (μm) Size / Format
    PTFEs 0.22 (022) 120 Roll
    0.45 (045) 150 Sheet
    1.20 (120) 200 Customizable
    - Customizable -

    Frequently Asked Questions (FAQ)

    What is the primary function of the Hydrophobic PTFE membrane in IV sets? ▼
    It functions as a venting device covering the distal end of the intravenous (IV) line. It prevents the flow and spillage of intravenous fluid to the outside environment while allowing entrapped air to escape.
    What support materials are available for the PTFE membrane? ▼
    The membrane comes with medical-class PET (Polyester) or PP (Polypropylene) support structures to ensure compatibility and mechanical strength.
    Can the PTFE membrane be sterilized using irradiation? ▼
    No, sterilization by irradiation is not available for this hydrophobic PTFE membrane.
    Why should I avoid using glue or cyclohexanone during installation? ▼
    Using glue or cyclohexanone for adhesion can clog the microporous structure of the PTFE material itself, which prevents gas and air from passing through.
    What dimensions and formats can be ordered? ▼
    We offer the membranes in rolls, sheets, or customized sizes. Standard thicknesses range from 120μm to 200μm, and pore sizes include 0.22μm, 0.45μm, and 1.2μm.