High-Quality 0.2μm Two-Side PTFE Membrane Filter for Medical Suction - China Suppliers & Factory

Introducing our high-performance suction filter, designed to safeguard sensitive components of suction devices from bodily fluids. The core of its effectiveness lies in the advanced hydrophobic PTFE (polytetrafluoroethylene) membrane, which is integral to our filtration system. Manufactured in our state-of-the-art factory in China, our 0.2µm two-sided PTFE membrane provides an exceptional filtration medium, ensuring efficient particle capture while preventing liquid contamination. This design not only protects critical equipment but also promotes adequate air circulation, making it ideal for various hospital suction systems. As leading suppliers in the market, we are committed to delivering reliable solutions that enhance the performance and longevity of medical devices

    Product Introduction
    Suction devices, which are frequently used in medical and healthcare settings, are susceptible to damage and contamination when they come into contact with bodily fluids. This susceptibility can compromise their functionality and pose significant health risks. To mitigate these issues, a suction filter is commonly used and placed between the suction pump and the secretion canister to prevent bacterial/viral and particulate contaminate from entering hospital suction system or equipment. A suction filter generally consists of two housings sealed around a filtering hydrophobic membrane, and the effectiveness of a suction filter to act as such a sterile barrier mainly depends on its key component: the hydrophobic PTFE (polytetrafluoroethylene) membrane built into the filter. Our custom-made 0.2-micron PTFE membrane is an ideal material for this application because it possesses several properties that make it exceptionally well-suited for this medical use.
    To achieve optimal performance, the custom designed binder-free PTFE membrane features two-side hydrophobic PTFE material, which means both faces of the membrane are PTFE, with exactly the same physical properties and high performance, making both faces suitable for being used as working face and reducing assembly mistakes. This PTFE laminated membrane filter is reinforced and durable with a maximum service-life of 24 hours and meets various operating conditions. Easy and convenient for further processing and assembly, available in roll and precut circle forms.
    Furthermore, PTFE material is highly hydrophobic, meaning it repels water and other liquids. Our PTFE membrane filter is designed, tested and processed so that it ensures that bodily fluids cannot penetrate the membrane under operation pressure of various suction systems, thereby protecting the internal components of the suction device from contamination and minimize significant health risks. Besides, PTFE is chemically inert, which means it does not react with or degrade when exposed to various chemicals commonly presenting in bodily fluids.
    In addition, the specially crafted microporous structure of our 0.2μm PTFE membrane allows adequate airflow to pass through while effectively blocking liquids, bacteria, aerosolized particles and other microorganisms with 99.9% efficiency, preventing any potential introduction of harmful contaminants into the suction system, reducing the risk of infections that could compromise patient health or equipment functionality.
    By integrating these two functions—effective liquid barrier protection and necessary airflow, the dual-layer PTFE membrane filter from us could support suction filter manufacturers who consider patient safety as highest priority to achieve their goal more easily, and more cost-wise.
    Features
    • Two-side of 0.2-micron PTFE
    • Bacterial retentive
    • Naturally hydrophobic
    • Broad chemical compatibility
    • High and stable air flow rate
    • Liquid barrier with high WBT pressure rating
    • High biosafety level
    • 100,000 grade cleanrooms manufactured
    • 100% Inspection
    PTFE membrane for medical suction filters 900 X 600
    Specifications
    Property Specification Details
    Material PTFE-PP/PTFE-PET
    Thickness 250μm, 400μm or custom
    Pore size 0.2μm
    Air flow rate ≥25ml/min@5kpa
    Water Break Through ≥3.0bar (43.5psi)
    Applications
    The two-side hydrophobic PTFE membrane filter is designed and manufactured in such a way that they can be used safely in many medical filter devices that would require a filtering hydrophobic membrane to act as a sterile barrier, including but not limited to:
    • Suction filters
    • Transducer protectors
    • EtCO2 filters (Capno Sampling Line Filter)
    • Bacterial filters
    • Medical breathing filters
    • Ventilator filters for breathing systems
    • Single-use vent filters
    Warnings
    • Handle with care to avoid damaging the filter material.
    • Sterilization by irradiation is not recommended.
    • Do not use glue or cyclohexanone for joining with housing as it will clog the material itself, preventing gas from passing through.
    • Avoid contact with alcohol or highly permeable solvents, otherwise, the material will become hydrophilic before it fully dries.
    Ordering Information
    Material Ref. Pore Size Thickness Membrane Size Lot No.
    PTFEp 022 025 Custom -
    Frequently Asked Questions (FAQ)
    Q: What is the primary function of the PTFE membrane in medical suction filters?
    A: The hydrophobic PTFE membrane acts as a reliable sterile barrier placed between the suction pump and the secretion canister. It prevents bodily fluids, bacteria, viruses, and particulate contaminants from entering the hospital suction system or equipment.
    Q: What are the advantages of a two-side hydrophobic PTFE membrane design?
    A: Both faces of the membrane share identical physical properties and high-performance standards. This allows either side to be used as the working face, which simplifies the manufacturing process and significantly reduces assembly errors.
    Q: What is the filtration efficiency and pore size of this PTFE membrane?
    A: The membrane features a 0.2μm microporous structure that permits adequate airflow while blocking liquids, bacteria, aerosolized particles, and microorganisms with a 99.9% efficiency rate.
    Q: Can this PTFE membrane filter be sterilized using irradiation?
    A: No, sterilization by irradiation is not recommended for this specific PTFE membrane material as it may compromise its structural integrity.
    Q: Why should glue or cyclohexanone be avoided during assembly?
    A: Using glue or cyclohexanone for joining the membrane with the housing will clog the microporous material, preventing necessary airflow and gas from passing through the filter.
    Q: What happens if the PTFE membrane contacts alcohol or solvents?
    A: Contact with alcohol or highly permeable solvents should be avoided because it will cause the naturally hydrophobic material to become hydrophilic before it completely dries, destroying its liquid barrier properties.