Leave Your Message
China XINNA Z26 IV Filters 2.0/3.0/5.0 μm - Quality Supplies from Trusted Factory Suppliers
Hot Products

China XINNA Z26 IV Filters 2.0/3.0/5.0 μm - Quality Supplies from Trusted Factory Suppliers

Discover high-quality products from reputable China suppliers and trusted factories. Our extensive range of goods is meticulously manufactured to meet international standards, ensuring durability and efficiency. By partnering with leading China suppliers, we guarantee that every item we offer is competitively priced while maintaining exceptional quality. Our factory's commitment to innovation and excellence allows us to provide you with the best products that cater to your specific needs. Explore our collection today and experience the reliability and craftsmanship that only the finest China suppliers can deliver
  • Category Z26
  • Filter Membrane Hydrophilic Polypropylene
  • Vent Hydrophobic PTFE
  • Housing ABS-based polymers
  • Removal of Particles options 2.0/3.0/5.0μm
  • Standard YY0286.1 GB8368-2018 ISO 8536-4

Product Introduction

Z26 Intravenous filter are air-eliminating (self-venting) filters with low protein binding Hydrophilic PP membrane for particulate debris, microbial contaminants and entrained air particle removal and bubble cancelation design interior for intravenous use.
Filter membrane: Hydrophilic Polypropylene (2.0-5.0μm) membrane is chemically and biologically inert on drugs delivery. And Membrane has been tested with multiple drugs and demonstrated to have broad drug compatibility.
We provide multiple outlet connectors for filters, which can adapt to various connecting tubes or for clinical use after sterilization in independent packaging. Moreover, lightproof colored housings are functional designed for light sensitive drugs that can effectively block the influence of light on the infusion fluid and ensure the stability and safety of the infusion fluid.

Features

  • Compact construction
  • Quick priming and air elimination
  • Low protein binding filter membrane
  • Various pore size options that enable retention of particles, bacteria and fungi
  • Range of connectors to accommodate a variety of tubing configurations
  • Amber or brown colored housing for light sensitive drugs
dics filter of infusion set application

Characteristics

Parameter Specification
Dimensions 51*31.6*13mm ( inlet/outlet connector included)
Connector Φ 3.1mm/3.6mm
Max burst pressure 3.6bar (52.5psi)
Venting air flow rate 10ml/min@5kpa
Priming volume ≤2.0ml
Operating temp 10-30℃
Pyrogenicity ≤0.5EU/ml
Storage temp 5-40℃
Sterilization Ethlene oxide (Max 60℃)

Performance

Z26  iv filter with PP

Package

  • 4000pcs/carton, 4 inner PE bags with 1000 pcs inside each. each bag is sealed separately and cushion between each other.
  • Each bag is labeled with information as following, different lots in one box are closed separately and labeled seperately to prevent mix up.

Label Information

Field Name Specifications Batch Information
Name Specifications Batch No.
Model Quantity Operator No.

Warnings

  • Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
  • Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling.
  • Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will break down.
  • Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
  • It's not recommended to use alcohol or any kind of disinfectant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
  • Blood delivery is not allowed, the filter clogs with blood or red blood cells.
  • Filters with 2μm filter media is not recommended for TPN and lipids administration.
  • Rigorous testing is recommended before marketing if drugs is not common.
  • Contact Xinna-Medical for more information if any doubt is exist advanced.

Ordering Information

Appearance Housing Filter Media Options Mold Connector Vents
GLOO 026 500 Z OY Y
GLBC 020 300 ON
200 1S

Frequently Asked Questions

What is the primary function of the Z26 Intravenous filter?

The Z26 Intravenous filter is an air-eliminating (self-venting) filter designed for intravenous use. It features a low protein binding hydrophilic PP membrane to effectively remove particulate debris, microbial contaminants, and entrained air bubbles.

What type of membrane is used in the filter and is it compatible with medications?

The filter utilizes a Hydrophilic Polypropylene (2.0-5.0μm) membrane that is chemically and biologically inert. It has been thoroughly tested with multiple drugs and demonstrates broad drug compatibility.

Can the Z26 filter be used for light-sensitive drugs?

Yes, the filter is available with amber or brown colored lightproof housings specifically designed to block the influence of light on light-sensitive drugs, ensuring the stability and safety of the infusion fluid.

What are the key technical specifications of the Z26 filter?

The filter has dimensions of 51*31.6*13mm (including connectors), a connector diameter of Φ 3.1mm/3.6mm, a maximum burst pressure of 3.6bar (52.5psi), a venting air flow rate of 10ml/min@5kpa, and a priming volume of ≤2.0ml.

What substances should not come into contact with the filter housing or membrane?

Alcohol must not contact the ABS-based housing, as it will cause damage. Additionally, alcohol or disinfectants should not directly contact the venting PTFE membrane, and glue must not contact the Hydrophilic PES membrane as it will cause the membrane to break down.

Can the Z26 filter be used for blood delivery or TPN administration?

No, blood delivery is not allowed because the filter will clog with blood or red blood cells. Furthermore, filters with 2μm filter media are not recommended for TPN (Total Parenteral Nutrition) and lipids administration.