Leave Your Message
China XINNA Z26 IV Filters 2.0/3.0/5.0 μm - High-Quality Suppliers from Trusted Factory
Hot Products

China XINNA Z26 IV Filters 2.0/3.0/5.0 μm - High-Quality Suppliers from Trusted Factory

Discover our high-quality products manufactured in China, where we collaborate with leading suppliers to ensure the best standards in craftsmanship and materials. Our factory is equipped with state-of-the-art technology, allowing us to produce innovative solutions that meet diverse customer needs. Whether you're looking for durability, efficiency, or cutting-edge design, our offerings stand out in the competitive market. Partner with us to benefit from unmatched quality and reliable service straight from our China-based factory. Experience the excellence that comes from working with top suppliers in the industry!
  • Category Z26
  • Filter Membrane Hydrophilic Polypropylene
  • Vent Hydrophobic PTFE
  • Housing ABS-based polymers
  • Removal of Particles options 2.0/3.0/5.0μm
  • Standard YY0286.1 GB8368-2018 ISO 8536-4

Product Introduction

Z26 Intravenous filter are air-eliminating (self-venting) filters with low protein binding Hydrophilic PP membrane for particulate debris, microbial contaminants and entrained air particle removal and bubble cancelation design interior for intravenous use.
Filter membrane: Hydrophilic Polypropylene (2.0-5.0μm) membrane is chemically and biologically inert on drugs delivery. And Membrane has been tested with multiple drugs and demonstrated to have broad drug compatibility.
We provide multiple outlet connectors for filters, which can adapt to various connecting tubes or for clinical use after sterilization in independent packaging. Moreover, lightproof colored housings are functional designed for light sensitive drugs that can effectively block the influence of light on the infusion fluid and ensure the stability and safety of the infusion fluid.

Features

  • Compact construction
  • Quick priming and air elimination
  • Low protein binding filter membrane
  • Various pore size options that enable retention of particles, bacteria and fungi
  • Range of connectors to accommodate a variety of tubing configurations
  • Amber or brown colored housing for light sensitive drugs
dics filter of infusion set application

Characteristics

Parameter Specification
Dimensions 51*31.6*13mm (inlet/outlet connector included)
Connector Φ 3.1mm/3.6mm
Max burst pressure 3.6bar (52.5psi)
Venting air flow rate 10ml/min@5kpa
Priming volume ≤2.0ml
Operating temp 10-30℃
Pyrogenicity ≤0.5EU/ml
Storage temp 5-40℃
Sterilization Ethylene oxide (Max 60℃)

Performance

Z26 iv filter with PP

Package

● 4000pcs/carton, 4 inner PE bags with 1000 pcs inside each. each bag is sealed separately and cushion between each other.
● Each bag is labeled with information as following, different lots in one box are closed separately and labeled separately to prevent mix up.

Label Information

Name Specifications Batch No.
Model Quantity Operator No.

Warnings

  • Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
  • Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling.
  • Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will break down.
  • Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
  • It's not recommended to use alcohol or any kind of disinfectant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
  • Blood delivery is not allowed, the filter clogs with blood or red blood cells.
  • Filters with 2μm filter media is not recommended for TPN and lipids administration.
  • Rigorous testing is recommended before marketing if drugs is not common.
  • Contact Xinna-Medical for more information if any doubt is exist advanced.

Ordering Information

Appearance Housing Filter media options Mold Connector Vents
GLOO 026 500 Z OY Y
GLBC 020 300 - ON -
- - 200 - 1S -

Frequently Asked Questions (FAQ)

What is the membrane material used in the Z26 Intravenous Filter?

The Z26 filter features a low protein binding Hydrophilic Polypropylene (PP) membrane (2.0-5.0μm), which is chemically and biologically inert and offers broad compatibility with various drugs.

Can the Z26 filter be used for blood delivery?

No, blood delivery is not allowed as the filter will clog with blood or red blood cells.

What are the storage and operating temperature requirements for the Z26 filter?

The recommended operating temperature is between 10-30℃, and the storage temperature should be kept within 5-40℃.

Are there options available for light-sensitive drugs?

Yes, we provide amber or brown colored housings designed specifically for light-sensitive drugs to block light and ensure the stability and safety of the infusion fluid.

How is the Z26 Intravenous Filter packaged?

The product is packaged with 4000 pieces per carton, containing 4 inner PE bags with 1000 pieces inside each. Each bag is sealed separately with protective cushioning.

Can alcohol be used to clean or disinfect the filter housing?

No, alcohol is not allowed to contact the housing, as it can cause visible or invisible damage to the ABS-based structure.