Leave Your Message
Precision Medical Filtration Engineering

0.2 Micron IV Filter For Particle Removal From IV Fluids

Advancing Patient Safety, Microvascular Integrity, and Infusion Purity through Advanced In-Line Membrane Technology & Dual-Layer Bacterial Retention

Featured In-Line & Bedside Filtration Devices

Engineered for high-flow particulate retention, endotoxin trapping, and bubble elimination across critical clinical applications.

XINNA D33 Dual filtration layer IV Filter 0.2/1.2 μm

XINNA D33 Dual filtration layer IV Filter 0.2/1.2 μm

High-performance dual-membrane PES filter designed for complete particulate interception, microbubble elimination, and extended gravity or pump-driven IV therapy.

Learn More
Two-side PTFE Membrane Filter 0.2μm Pore Size for Medical Suction Filters

Two-side PTFE Membrane Filter 0.2μm Pore Size

Hydrophobic polytetrafluoroethylene membrane engineered specifically for high-efficiency bacterial barriers and medical suction equipment protection.

Learn More
Vented Admixture Device with Snap Cap for Drug Reconstitution and Transfer

Vented Admixture Device with Snap Cap

Integrated 0.22μm air-venting spike designed for sterile drug reconstitution, preventing aerosol release and particulate introduction during compounding.

Learn More
Needle-free Y Site Connector For Infusion set

Needle-free Y Site Connector For Infusion Set

Closed-system luer-activated access site providing high microbial resistance, preventing coring particulate generation and reducing touch contamination risks.

Learn More

01 The Clinical Imperative: Pathophysiology of Particulates in Intravenous Therapy

Intravenous (IV) therapy represents one of the most widely practiced clinical interventions globally, delivering life-saving hydration, total parenteral nutrition (TPN), oncology regimens, blood derivatives, and complex biopharmaceuticals. However, the infusion of unfiltered or sub-optimally filtered fluids carries a profound yet frequently underappreciated clinical hazard: particulate matter contamination. Foreign particulates within IV administration sets originate from diverse physical and chemical mechanisms, including glass micro-shards generated during the snapping of glass ampoules, elastomer coring fragments sheared from rubber vial stoppers during needle penetration, insoluble drug-drug precipitants, calcium-phosphate crystalline complexes in parenteral admixtures, and sub-visible silicone oil droplets or ambient contaminants.

When infused into the human vascular circulation, particles exceeding capillary diameters (typically 5 to 10 micrometers) are physically arrested within the microvascular beds of primary capillary networks, particularly the pulmonary microvasculature, hepatic sinusoids, renal glomeruli, and cerebral capillary networks. The clinical sequelae of systemic microvascular occlusion encompass endothelial mechanical erosion, secondary platelet aggregation, sterile systemic inflammatory response syndrome (SIRS), localized thrombophlebitis, foreign-body pulmonary granulomatosis, and impaired end-organ perfusion. In fragile patient cohorts—such as neonates, pediatric intensive care patients, critically ill surgical patients, and immunocompromised oncology patients—the cumulative load of infused sub-visible particulates directly correlates with systemic inflammatory cascade activation, prolonged mechanical ventilation duration, and heightened multiorgan dysfunction incidence.

The 0.2 micron IV filter serves as the definitive physiological barrier against this insidious vascular insult. Designed with an absolute pore size threshold capable of intercepting not merely visible and sub-visible macro-particulates, but also vegetative bacteria (such as Pseudomonas aeruginosa, Staphylococcus aureus, and Klebsiella pneumoniae), fungi, and endogenous macromolecular aggregates, the 0.22 μm in-line membrane represents the ultimate line of defense for bedside patient safety.

02 Membrane Science: Polyethersulfone (PES) vs. Nylon vs. PTFE in 0.2 Micron IV Filtration

The operational performance of a clinical 0.2 micron IV filter is dictated by membrane polymer morphology, surface chemical charge, asymmetric pore architecture, and mechanical shear integrity. Unlike nominal filtration systems that rely on deep tortuous mechanical entrapment, absolute 0.2 micron membranes must demonstrate a definitive bubble point integrity threshold and log reduction value (LRV > 7) for Brevundimonas diminuta according to ASTM F838 standards.

Membrane Material Wettability / Hydrophilicity Protein Binding Affinity Chemical Compatibility Primary Medical Applications
Polyethersulfone (PES) Inherently / Modified Hydrophilic Ultra-Low Binding (< 1.5 μg/cm²) Broad (pH 1–13, alcohols, lipids) In-line IV infusion, biologics, chemotherapy, TPN lipid emulsions
Polytetrafluoroethylene (PTFE) Naturally Hydrophobic (Dual-Sided) Low Adsorption Extreme (Universal solvents, gases) Bacterial air vents, transducer protectors, CO2 sampling, gas insufflation
Nylon (Polyamide PA66) Hydrophilic Moderate to High Binding Resistant to organic solvents General aqueous filtration, disc infusion filters, prep-filtration
Polyvinylidene Fluoride (PVDF) Hydrophobic / Modified Hydrophilic Very Low High (Oxidizing agents, acids) Sterilizing gas vents, diagnostic bioprocess filtration

Modern advanced IV in-line filters integrate asymmetric, multi-layer PES membranes. Asymmetry denotes an engineered gradient pore structure where the upstream face features larger pore dimensions (e.g., 1.2 μm or 0.8 μm) that perform integral pre-filtration, capturing larger crystalline complexes and elastomer fragments without creating premature surface cake formation. The fluid then transitions through the dense downstream 0.2 micron retention matrix, ensuring extended flow rates throughout 96-hour continuous infusions without premature clogging or clinical pressure drop spikes.

Furthermore, state-of-the-art IV filter housings incorporate self-priming, hydrophobic 0.02–0.2 μm PTFE venting membranes positioned orthogonally to the fluid flow path. This dual-membrane architecture ensures automatic, continuous purging of entrained air bubbles (eliminating air embolism risks) regardless of patient positioning or gravity orientation, while completely retaining the aqueous drug formulation within the fluid path without external weeping.

1994
Established in
30+
Years R&D Experience
80+
Patents Worldwide
161,458+
Sq Feet Manufacturing Area
About Our Manufacturing Excellence

Engineering Sterile Filtration Solutions for Over Three Decades

As a high-tech enterprise integrating research and development, production, and sales, we provide a wide assortment of membranes with different performance characteristics, making it easy for you to find the membrane that exactly fits your application. In addition, we have more than 30 years of extensive membrane manufacturing experience and deep expertise in related regulatory compliance, in cases where the available membranes or devices are not ideal for your application, our sales and R&D team will work closely with you to create tailormade and reliable solutions to meet your specific application requirements.

The extensive collection of microporous filter medium and devices we provide are specifically designed and optimized for various medical and healthcare applications, such as for infusion therapy, drug delivery and transfer, and medical equipment protection. The microporous filter materials are manufactured under highly controlled conditions with quality systems certified to ISO 9001. Among our 161,458 square feet manufacturing facilites, 75,347 square feet are Class 100,000 cleanroom. This clean production environment enables us to provide customers with higher levels of cleanliness and contamination-free product status.

Cleanroom Filtration Manufacturing Facility

Product Categories & Filtration Mediums

High performing and affordable filtration materials and devices for medical device manufacturers and healthcare professionals.

Liquid Filtration Membranes

Medical Filtration Membranes

Hydrophilic membranes are suitable for filtering aqueous solutions, retaining larger particulates and reducing the risk of bacterial contamination during IV drug preparation and long-term infusion therapy.

Explore Our Products
Medical Venting Membranes

Medical Venting Membranes

Hydrophobic membranes manufactured of advanced microporous materials, to be used as components of medical and healthcare devices for venting, gas sterilization, and dynamic pressure equalization.

Explore Our Products
Healthcare Filters and Accessories

Healthcare Filters & Accessories

XINNA carries a broad range of trusted healthcare filters, accessories and consumables, such as IV filters, Bacterial air vents, TP filter, transfer spikes and more. Integrating these micron filters into IV tubing sets helps remove air from the line and retain bacteria.

Explore Our Products

Comprehensive Clinical & Industrial Application Scenarios

Tailored microporous membrane engineering across critical therapy sectors, hemodialysis circuits, respiratory pathways, and closed fluid transfer systems.

Infusion Therapy Applications

Infusion Therapy & Microvascular Defense

Manufactured according to ISO standards, our wide assortment of membranes provides diverse performance characteristics, making it easy for you to find the best membrane to fit your application. In high-risk infusion therapies—such as pediatric intensive care, oncology chemotherapy delivery, and parenteral nutrition—our 0.2 micron IV filters prevent vascular inflammation, reduce thrombophlebitis occurrence by up to 70%, and eliminate air embolism hazards.

● IV filters ● Extension lines with IV filter ● Infusion filtration membranes ● Spike venting membranes ● IV catheter venting membranes ● Drip Chambers & Infusion Disc Filters

Our dual-layer PES membrane architecture provides ultra-low protein binding properties, ensuring that therapeutic monoclonal antibodies, paclitaxel, or insulin regimens maintain their exact bioavailability without active drug adsorption onto the housing or filter matrix.

Haemodialysis Applications

Haemodialysis & Blood Line Protection

Manufactured according to ISO standards, our transducer protectors are the filter of choice for Fortune 500 medical device manufacturers. The 0.22 micron Hydrophobic PTFE membrane allows only sterile air to pass through while acting as an impenetrable barrier against blood and dialyzing fluid from damaging sensitive electronic pressure transducers.

● Transducer Protector venting membranes ● TP filters ● Dialysate Endotoxin Barriers ● Extracorporeal Circuit Protectors

With such filter media built-in, transducer protectors (TP filters) are widely utilized in hemodialysis blood lines, continuous renal replacement therapy (CRRT), and extracorporeal life support systems to protect both patients and hospital equipment from cross-contamination and fluid breakthrough.

Respiratory & Venting Applications

Respiratory, Insufflation & Gas Venting

Manufactured according to ISO standards, our respiratory filters integrate high-quality hydrophobic bacterial filter media capable of preventing bacteria, moisture, aerosols, and biological secretions from entering medical gas pathways while maintaining clean laminar flow and accurate capnography waveforms.

● CO2 Sampling filter ● Nasal cannula filter ● Suction unit filters ● Insufflation Filters ● Insufflation Filter Membranes ● Bacterial Air Vents Membranes

Available with 0.22μm pore size PTFE membranes, medical-grade ultrasonic-welded ABS or acrylic housings, and universal luer-lock connectors, ensuring reliable performance in laparoscopic insufflation, anesthesia gas analysis, and surgical smoke evacuation.

Fluid Transfer & Needle-Free Connectors

Fluid Transfer, Reconstitution & Needle-Free Systems

Single-use transfer devices engineered to make the reconstitution, aspiration, and addition of critical medications safe, sterile, and rapid. These admixture devices are ideal for transferring fluids from drug vials to IV infusion bags without aerosol contamination or drug wastage.

● Mini Spikes ● Bag / Vial Transfer Spikes ● Spike Adapters ● Needle-Free IV Connectors ● Precision Luer Fittings

Fully compatible with 50 mL, 100 mL, 250 mL, and 1000 mL IV bags. The integrated 0.22 μm hydrophobic air-venting filter delivers dual protection: shielding pharmacy compounding staff against toxic cytotoxic aerosols while preventing microbial intake during atmospheric air replacement.

Clinical Application Segments

Validated precision filtration medium deployed across international intensive care units and healthcare manufacturing facilities.

Infusion Therapy

Infusion Therapy

Protecting microvascular systems through continuous 0.2 μm in-line filtration of critical medications and TPN.

Respiratory & venting

Respiratory & Venting

Sterile gas barriers and micro-pore filtration for anesthesia lines, ventilators, and surgical aspirators.

Hemodialysis

Hemodialysis

Transducer protectors and hydrophobic PTFE membranes preventing cross-contamination in dialysis machines.

Fluid Transfer & Filtration

Fluid Transfer & Filtration

Vented spikes, needle-free reconstitution devices, and compounding consumables for sterile drug preparation.

03 Regulatory Frameworks: USP <788>, EP 2.9.19 & ISO 8536 Standards

International regulatory authorities and pharmacopoeias maintain stringent thresholds governing allowable particulate quantities in parenteral solutions. The United States Pharmacopeia (USP) general chapters USP <788> (Particulate Matter in Injections) and USP <787> (Sub-visible Particulate Matter in Therapeutic Protein Injections), alongside the European Pharmacopoeia (EP 2.9.19) and Japanese Pharmacopoeia (JP 6.07), establish light obscuration and microscopic particle count limits for particles ≥ 10 μm and ≥ 25 μm in parenterals.

However, modern clinical pharmacology confirms that particles in the 0.2 to 5.0 μm range—which are sub-visible and not counted in standard USP release tests—represent the vast majority of circulating foreign bodies. This reality has driven major clinical societies (including the Infusion Nurses Society - INS, and the American Society for Parenteral and Enteral Nutrition - ASPEN) to mandate or strongly recommend the standard incorporation of 0.2 micron in-line IV filters for all non-lipid aqueous infusions, all-in-one parenteral nutrition admixtures (incorporating 1.2 μm filters), and high-risk biological preparations.

From an industrial manufacturing perspective, our medical filters comply strictly with ISO 8536-4 (Infusion equipment for medical use), ISO 10993 (Biological evaluation of medical devices for cytotoxicity, sensitization, hemolysis, and systemic toxicity), and European CE marking medical directives. Our Class 100,000 cleanrooms operate under dynamic particle monitoring, automated continuous ultrasonic welding, and 100% in-line bubble point integrity and housing burst pressure testing.

04 Technological Trends: Low Protein Adsorption, Nanofiber Matrices & Smart Infusion

The rapid proliferation of complex biotherapeutic agents—including monoclonal antibodies (mAbs), antibody-drug conjugates (ADCs), recombinant cytokines, and mRNA-lipid nanoparticle formulations—has imposed unprecedented demands on IV filtration media. Conventional membranes with non-specific hydrophobic binding sites can cause the selective depletion of high-value active pharmaceutical ingredients (APIs), altering the administered dosage.

Next-generation 0.2 micron filters address this challenge through advanced hydrophilic surface graft polymerization (such as zwitterionic polymer coatings and neutral PEG hydrogel brushes), reducing non-specific protein binding to virtually undetectable levels (< 0.5 μg/cm²). Concurrently, the integration of electrospun polyacrylonitrile (PAN) and high-flux bi-component polymer matrices enables high gravity flow rates (> 350 mL/min at standard hydrostatic heads) despite the sub-micron pore architecture.

Furthermore, in the era of smart digital hospital wards, smart infusion sets are emerging with integrated non-invasive optical sensor ports and RFID-tagged micro-filter housings, allowing automated tracking of filter lifespan, pressure differential buildup, and timely clinical replacement alerts prior to therapeutic interruption.

Why Choose Our Medical Filtration Solutions

A trusted global supplier delivering high-cleanliness medical devices and custom membrane engineering.

  • ● 30+ Years Experience: Extensive experience of manufacturing and innovation in providing medical filtration products and critical device engineering.
  • ● 75,347 sq. feet Class 100,000 Cleanroom: Strict QC and analytical bioburden / endotoxin testing to guarantee supreme product quality and clinical safety.
  • ● 46,000,000+ Pcs Annual Supply: Healthcare filter devices were supplied worldwide annually with zero critical defect recall rates.
  • ● Top Sales in China: Leading manufacturer and distributor of microporous membrane filters for medical applications nationwide.
  • ● Partner to TOP 5 & Fortune 500: Regular trusted supplier of the TOP 5 medical device manufacturers in China and global Fortune 500 healthcare enterprises.
  • ● Broad Polymer Portfolio: Hydrophilic and hydrophobic membranes, including PES, Nylon, PTFE, PVDF, PET, PP, and Glass Fibre for medical, bio-pharma, and diagnostics.

Get In Touch With Our Engineering Team

Our technical and customer support teams always focus on the needs and satisfaction of our customer and are able and flexible to provide, optimize or develop products to solve your challenging filtration issues. It's been our constant commitment to supporting our customers with products that meet both their budget and performance expectations, and to doing our part effectively to speed up the launch time of customer's finished products to market.

Request Technical Consultation & Samples