XINNA Z26 IV Filter 2.0/3.0/5.0 μm
Product Introduction
Z26 Intravenous filter are air-eliminating (self-venting) filters with low protein binding Hydrophilic PP membrane for particulate debris, microbial contaminants and entrained air particle removal and bubble cancelation design interior for intravenous use.
Filter membrane: Hydrophilic Polypropylene (2.0-5.0μm) membrane is chemically and biologically inert on drugs delivery. And Membrane has been tested with multiple drugs and demonstrated to have broad drug compatibility.
We provide multiple outlet connectors for filters, which can adapt to various connecting tubes or for clinical use after sterilization in independent packaging. Moreover, lightproof colored housings are functional designed for light sensitive drugs that can effectively block the influence of light on the infusion fluid and ensure the stability and safety of the infusion fluid.
Features
- Compact construction
- Quick priming and air elimination
- Low protein binding filter membrane
- Various pore size options that enable retention of particles, bacteria and fungi
- Range of connectors to accommodate a variety of tubing configurations
- Amber or brown colored housing for light sensitive drugs
Characteristics
| Dimensions | 51*31.6*13mm ( inlet/outlet connector included) |
| Connector | Φ 3.1mm/3.6mm |
| Max burst pressure | 3.6bar (52.5psi) |
| Venting air flow rate | 10ml/min@5kpa |
| Priming volume | ≤2.0ml |
| Operating temp | 10-30℃ |
| Pyrogenicity | ≤0.5EU/ml |
| Storage temp | 5-40℃ |
| Sterilization | Ethlene oxide (Max 60℃) |
Performance

Package
● 4000pcs/carton, 4 inner PE bags with 1000 pcs inside each. each bag is sealed separately and cushion between each other.
● Each bag is labeled with information as following, different lots in one box are closed separately and labeled seperately to prevent mix up.
Label information
| Name | Specifications | Batch No. |
| Model | Quantity | Operator No. |
Warnings
● Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
● Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling.
● Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will break down.
● Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
● It's not recommended to use alcohol or any kind of disinfectant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
● Blood delivery is not allowed, the filter clogs with blood or red blood cells.
● Filters with 2μm filter media is not recommended for TPN and lipids administration.
● Rigorous testing is recommended before marketing if drugs is not common.
● Contact Xinna-Medical for more information if any doubt is exist advanced.
Ordering information
| Appearance | Housing | Filter media options | Mold | Connector | Vents |
| GLOO | 026 | 500 | Z | OY | Y |
| GLBC | 020 | 300 | ON | ||
| 200 | 1S |