XINNA F33 IV Filter 1.2/2.0/3.0/5.0μm for infusion sets
Product Introduction
Potential risks caused by harmful particles, microbial contamination, and air micro embolism should be considered in infusion therapy, drug preparation, and mixing processes. F33 IV filter is designed for use in filtration of intravenous for removal of particles large than 1.2/2.0/3.0/5.0μm.
F33 IV Filter is an air eliminating filter for the removal of inadvertent particulate debris and other components like incomplete mixing of drugs and entrained air in catheter which may be found in solutions intended for intravenous use. The filtration efficiency of the membrane and the overall design of the filter can impact the safety of drug delivery for human beings.
It is inbuilt with low binding Hydrophilic Polypropylene filter membrane lower the loss of drug and active ingredients, and dual vents design allows air elimination in any position. ensuring the safety and effectiveness of intravenous.
Features
- Range of pore size options
- Low protein binding & Low dissolution
- Dual vent design ensures quick Priming and air elimination
- Compatibility with TPN & chemotherapeutic agents
- Maximizes filtration area with compact construction
- Lightproof-colored housings for light sensitive drugs is available
- Printing available for ease of product identification
Characteristics
| Dimensions | 57*29*0.94mm ( inlet/outlet connector included) |
| Connector | Φ 3.1mm/3.6mm |
| Max burst pressure | 3.6bar (52.5psi) |
| Priming volume | ≤2.0ml |
| Venting air flow rate | 25ml/min@5kpa |
| Operating temp | 10-30℃ |
| Pyrogenicity | ≤0.5EU/ml |
| Storage temp | 5-40℃ |
| Sterilization | Ethlene oxide (Max 60℃) |
Performance

Package
3000pcs/carton, 4 inner PE bags with 750 pcs inside each. Each bag is sealed separately and cushion between each other.
Each bag is labeled with information as following, different lots in one box are closed separately and labeled seperately to prevent mix up.
Label information
| Name | Specifications | Batach No. |
| Model | Quantity | Operator No. |
Warnings
● Filter for medical use, assembled in clean room only. Remove the external bag before planting into a clean room.
● Handle with care. Keep filter in vertical position with flow arrow on both sides and the printing mark before assembling. Be careful on glueing, if Hydrophilic PES membrane contact with glue, membrane will breaks down.
● Alcohol is not allowed to contact with housing, or it will damage the ABS-based housing visible or invisible.
● It's not recommended to use alcohol or any kind of disinfactant in direct contact with venting membrane, PTFE membrane will become hydrophilic until dried.
● Blood delivery is not allowed, the filter clogs with blood or red blood cells. Filters with 0.2μm filter media is not recommended for TPN and lipids administration.
● Rigorous testing is recommended before marketing if drugs is not common.
● Contact with Xinna Medical for more information if any doubt is exist advanced.
Ordering information
| Appearance | Housing | Filter media options | Mold | Connector | Vents |
| GLOL | 033 | 500 | F | OY | Y |
| GLBC | 300 | ||||
| GLBZ | 200 | ||||
| 120 |